Back to search

Iowa State University

Electromagnetic biosensor development: towards smart biomanufacturing and personalized regenerative medicine

Abstract

dc:description.abstract

Biosensors providing critical information about biological systems are key for advancing toward biomanufacturing 4.0 and elucidating intricate biological interactions. Numerous assays and analytical technologies have been developed to probe biological systems in vitro. However, most assays are limited to end-point measurements, which lack dynamic information, involve lengthy preparation steps, and lack real-time control capabilities. The development of real-time and high-content biosensors is crucial for a more detailed understanding and effective screening for personalized medicine. In the first chapter, an overview of the biosensor components, which consist of bioreceptors and transducers, is provided, with an emphasis on electromagnetic wave transduction methods due to their non-invasive measurement capabilities. More specifically, the design considerations of biosensors based on optical and radio wave methods are discussed. We show that an inductive-capacitive resonant sensor, which is wireless, label-free, and versatile in different biological system platforms, is an attractive option for transduction. The remainder of the thesis is classified into two parts: 1) manufacturing and engineering sensing modalities of resonant sensors, and 2) biosensor development employing resonant sensors. In Chapter 2, the fabrication of resonant sensors using screen printing, chemical etching, and wire winding methods is investigated for large-scale manufacturing capability. We show that the screen printing method is a low-cost, high-efficiency option for the large-scale fabrication of resonant sensors. Additionally, resonant sensors often involve signal noise resulting from the position of interrogation. In Chapter 3, we demonstrate that this position-dependency can be mitigated by introducing an inductive-capacitive extender (ICE). The ICE decouples the parasitic capacitance between the sensor and the reader, resulting in over 10-fold reduction in noise from varying interrogation positions. When applying resonant sensors for sensing, two forms of sensing modalities, direct and indirect, can be achieved. The chapter further demonstrates the sensing of soil moisture via direct sensing, in which permittivity is reflected by the water content, resulting in a 4.52 %moisture content/MHz sensitivity. In Chapter 4, an indirect sensing modality is demonstrated by sensing temperature transduced by temperature-sensitive fluids. A low-cost microfluidic channel fabricated by laser ablation is coupled with a resonant sensor to enable working with low-volume fluid at high sensitivity. Temperature induces fluid flow, which results in permittivity change used to detect temperature perturbations in cold and ultra-cold environments. These chapters sum up the basics of sensing principles and engineering strategies involved in resonant sensor development. The second part of the thesis focuses on the development of resonant sensors in biological systems. In Chapter 5, a brief overview of the biomedical applications resulting from resonant sensors is provided, involving in vivo and ex vivo targets. Challenges of resonant sensors in biomedical applications, including environmental interference on signal and low sensitivity, are discussed, showing the need for engineering strategies to enable biosensing. In Chapter 6, we investigated the permittivity of biological cultures using direct and indirect approaches. We demonstrated that the intrinsic permittivity does not provide sufficient sensitivity, disabling direct sensing with resonant sensors. We further developed a novel indirect sensing approach using polyacrylates as bioreceptors. In this work, polyacrylate is discovered to continuously absorb secreted metabolites, which is correlated with cell proliferation of many cell lines, including K562, HeLa, and Chinese hamster ovary cells. Polyacrylate is integrated with resonant sensors to form the single-use, metabolite absorbing, resonant transducer (SMART), demonstrating the ability to monitor cultures in real time, which can be applied in bioproduction. In Chapter 7, we demonstrate the utility of SMART in more complex systems involving co-cultures of immune and tumor cells. By monitoring the coculture between NK92 and K562 cells using SMART, we demonstrate that the cytotoxic/anti-proliferation effect can be continuously monitored. In the final chapter, we conclude with a summary of the work and discuss the future direction of the developed methods and technologies.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Discipline thesis:degree_discipline
Chemical engineering
Department dc:contributor.department
Department of Chemical and Biological Engineering
Grantor
Iowa State University
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chan, Yee Jher
Advisors dc:contributor.advisor
  • Reuel, Nigel
  • Mallapragada, Surya
  • Schneider, Ian
  • Bardhan, Rizia
  • Nilsen-Hamilton, Marit

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Chan, Yee Jher. Electromagnetic biosensor development: towards smart biomanufacturing and personalized regenerative medicine. dissertation thesis, Iowa State University, 2024. https://doi.org/10.31274/td-20250502-203