Iowa State University
Liquid plug displacement and pendant drops: experiments and stability analysis
Abstract
dc:description.abstractThe stability of pendant drops suspended in air and the displacement of liquid plugs by pressurized air are studied. The former topic is of primary interest in the investigation and further development of novel evaporation-based lithographic techniques, whereas the latter analysis on pressure-driven plug flow is useful to various microfluidic technologies. \\ In the first problem, we studied the pressure-driven displacement experiments using aqueous glycerol liquid plugs at low pressures. Experiments were performed in a capillary tube (diameter $\approx$ 800 μm) by displacing liquid plugs containing aqueous glycerol solution using pressurized air with a range of 0.02 $< P <$ 0.2 psig. At certain pressures ($P <$ 0.07 psig), film rupture or reversal was observed, and therefore these experimental results were further studied theoretically using perturbation analysis. It has been shown that in the limit of low $Re$, when a right circular cylindrical plug is displaced at a constant flow rate in a confined cylindrical geometry, an analytical solution can be found by solving the 4th - order stream function equation - E2 (E2 \psi)=0. By utilizing the general solution to the 4th - order stream function PDE and applying boundary conditions derived using perturbation analysis of pressure-driven flow, we obtain an analytical solution representing the leading-order behavior of the perturbed system. This leading-order solution describes an undeformed right circular cylindrical plug. We analyze this leading-order solution at a zero capillary number to compare with experimental results from pressure-driven displacement tests.\\ In the second problem, we studied the stability of pendant drops suspended from a syringe needle tip using theory and experiments. Here, we applied an eigenvalue analysis to the Young-Laplace equation for pendant drops to predict the instability type and critical drop volume that detaches and falls from a syringe needle tip due to gravity. Pendant drop experiments were performed using different liquids and syringe needle sizes for a wide range of Bond numbers, 0.2 < Bo* < 1.2. Liquid drops were generated using a syringe that was mounted on a vertically oriented syringe pump that drove the syringe's plunger at a very low flow rate (1 μl/min - 50 μl/min). Experiments were performed at room temperature and typically lasted between 5 - 35 min, where evaporation of drops is significant for volatile fluids. We used needles with an outer diameter in the range 0.3 mm \leq Rsyr \leq 9.6 mm, and liquids: water, denatured alcohol, 5 cSt silicone oil, and glycerol for these experiments. Experimental results that included pinched-off drop volumes were compared with values computed at their stability limit from the eigenvalue analysis. The stability analysis can predict axisymmetric and asymmetric instabilities, and the agreement between volumes at pinch-off found through numerical and experimental analysis depended on the Bond number. \\ In the third problem, we investigated the pressure-driven displacement of aqueous glycerol Ca(OH)2 liquid plugs using air or CO2 gas in a capillary tube. We utilize this less-explored displacement method to evaluate the feasibility of CO2 sequestration by exploiting the chemical reaction between aqueous glycerol Ca(OH)2 and dissolved CO2, which forms calcium carbonate in a confined region. This approach offers a permanent sequestration solution that is cost-effective and energy efficient. Liquid plugs, consisting of either 90\% or 95\% (v/v) aqueous glycerol mixed with Ca(OH)2, were displaced at various concentrations and lengths using CO2 or air at pressures ranging from 0.2 to 1.0 psig. The displacement experiments with air serve as a no-chemical reaction case, while those with CO2 gas are used to study the chemical reaction case. Image analysis of the displacement experimental data was performed to estimate the residual fluid fraction, m=1- (Um/Ut), left along the walls of the capillary tube. The $m$ versus capillary number, $Ca$, plots for 90\% and 95\% aqueous glycerol Ca(OH)2 liquid plugs show that the residual fluid fraction $m$ is significantly higher for the chemical reaction case compared to the no-chemical reaction case, especially at low $Ca$. Additionally, the 90\% plugs exhibit a greater increase in $m$ value under chemical reaction conditions compared to the 95\% plugs. This increase in $m$ value in chemical reaction cases suggests the possibility of CaCO3 precipitate formation, which is more prominent at low $Ca$ and lower glycerol content.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- dissertation
- Discipline thesis:degree_discipline
- Fluid mechanics
- Department dc:contributor.department
- Department of Aerospace Engineering
- Grantor
- Iowa State University
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Sasetty, Sravya
- Advisors dc:contributor.advisor
-
- Ward, Thomas
- Hu, Hui
- Xiong, Liming
- Ganapathysubramanian, Baskar
- Beresnev, Igor
- ORCID dc:identifier.orcid
Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://dr.lib.iastate.edu/handle/20.500.12876/azJ4ABPv