Back to search

Iowa State University

Assessment, repair, and replacement of bridges subjected to fire

Abstract

dc:description.abstract

Although bridge failures resulting from fire are not as common as other failures (scour, collision, wind, etc.), they still pose impacts on safety, traffic flow, and owner budgets as repairs or replacements can be costly. Due to the lack of technical information and guidance needed to evaluate fire damage on concrete bridges, this research was conducted to aid bridge owners in their decisions for both immediate and long-term use of prestressed concrete girder bridges subjected to fire. A fire under the I-29 northbound bridge over Perry Creek Conduit in Sioux City, Iowa was exacerbated when a propane tank used in a homeless encampment exploded on October 30, 2019. Due to the low ground clearance beneath this single-span precast prestressed concrete beam bridge, the fire had impacted multiple girders underneath, leading to exposed strands and stirrups throughout the bridge. Although the explosion was an unfortunate incident, the fire-damaged girders provided an opportunity to learn more about the residual strength and serviceability of the bridge. The Iowa Department of Transportation (DOT) elected for the removal and replacement of the bridge, allowing the girders to undergo testing. Three fire-damaged girders were selected from the I-29 Sioux City bridge. They were removed and transported to the Iowa DOT Maintenance Garage in Ames, Iowa. The girders were visually assessed and selected for structural tests based on the apparent level of damage incurred; one low-level, one mid-level, and one high-level. The goal was to compare the effects of various levels of damage and assess the impacts the fire event had on the serviceability and strength of the bridge. The results from the load and material tests revealed that the intensity (temperature) and duration of the fire did not have significant impact on the load carrying capacity. The damage did not progress beyond the concrete cover and the structural integrity of the girders was not compromised. Surface-level repairs were recommended to protect the steel reinforcement. This research built and expanded on the information and data collected from other published research studies to provide recommendations to minimize fire damage on bridges through suggestions for fire prevention policies and management strategies. The outcome provided technical guidance regarding the evaluation of fire-damaged girders to assist bridge owners in their decision to repair or replace fire-damaged bridges.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Discipline thesis:degree_discipline
Civil engineering
Department dc:contributor.department
Department of Civil, Construction and Environmental Engineering
Grantor
Iowa State University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Afzal, Rabia
Advisors dc:contributor.advisor
  • Sanders, David
  • Cho, In-Ho
  • Smadi, Omar
  • Shane, Jennifer

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Afzal, Rabia. Assessment, repair, and replacement of bridges subjected to fire. thesis thesis, Iowa State University, 2023. https://doi.org/10.31274/td-20240617-229