Voltage stability limits for weak power systems with high wind penetration

Abstract

dc:description.abstract

Analysis of power system voltage stability has practical value in increasing wind penetration levels. As wind penetration levels increase in power systems, voltage stability challenges arise due to locating wind resources far away from load centers. This dissertation presents several different voltage stability methods for sizing new wind farms. Power system wind penetration levels depend on the available voltage stability margins (VSMs) of the existing power system and system load characteristics. Three new iterative methods have been developed to maximize wind penetration level in weak power systems based on systems’ VSMs. The first two methods use an iterative approach for increasing the size of each wind farm until reaching the collapse point. Wind farms with less negative impact on system VSMs are sized larger than others. A third wind farm sizing method has been developed using modal analysis in conjunction with the traditional voltage stability method (Q-V method). Wind farms are placed at buses in the power system which have the lowest negative impact on voltage instability modes (strong wind injection buses). By placing the wind farms at the strongest wind injection buses, higher amounts of wind power can be injected into the power system. To further increase wind penetration in weak power systems, two additional techniques are introduced and applied to the western Kansas power system. The first technique uses modes of voltage instability to place voltage support equipment like static var compensators at locations in the power system where they provide the needed reactive power support for increasing levels of wind penetration. The second technique uses the fact that wind patterns at a wind farm site may rarely allow the wind farm to produce its maximum capacity during the peak loading hours. Wind farm maximum sizes can be increased above their maximum voltage stable size limit without driving the power system into becoming voltage unstable. Preventing voltage collapse for the additional increases in wind farm sizes is accomplished by disconnecting some wind turbines inside the wind farm during critical times to reduce its power output to a voltage stable level.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Department of Electrical and Computer Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tamimi, Ala
Advisors dc:description.advisor
  • Anil Pahwa
  • Shelli K. Starrett

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/13100

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Tamimi, Ala. Voltage stability limits for weak power systems with high wind penetration. Doctoral thesis, Kansas State University, 2011. https://hdl.handle.net/2097/13100