Kansas State University
Examining the effects of openings at the base of slender reinforced concrete (tilt-up) wall panels subjected to varying wind pressures
Abstract
dc:description.abstractThis report examines the effects of openings located at the base of reinforced concrete slender wall panels (tilt-up panels) designed in accordance with the American Concrete Institute (ACI) Committee 318-11 Building Code Requirements for Structural Concrete Section 14.8 Alternative Design of Slender Walls. The parametric study calculates the reinforcement (longitudinal) required for specific panels in accordance with ACI 318-11 Section 14.8 and compares the designs to a finite element analysis conducted with SAP 2000 version 14 to determine the appropriateness of the assumptions made in Section 14.8. Furthermore, this report compares the design of a tilt-up panel designed by Section 14.8 Alternative Design of Slender Walls and designed by Section 10.10 Slenderness Effects in Compression Members.
Degree
thesis:*- Level thesis:degree_level
- Masters
- Department dc:contributor.department
- Department of Architectural Engineering and Construction Science
- Grantor dc:publisher
- Kansas State University
- Year dc:date.issued
- 2011
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Cook, Andrew
- Advisor dc:description.advisor
-
- Kimberly W. Kramer
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
- Licence dc:rights.uri
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2097/13166