Back to search

Kansas State University

Selective coordination for overcurrent protective devices: applications for buildings in the United States

Abstract

dc:description.abstract

The inclusion of Selective Coordination in the NEC since the 2002 revision and the expansion of applications for which coordination of Over-current Protective Devices is required have resulted changes in design approaches for electrical engineers. In order to meet the requirements of the NEC regarding Selective Coordination for secondary power systems within buildings, often, upstream protective devices need to be held-in to a short-circuit condition, thus increasing the Arc Flash Energy. Electrical engineers must understand the many aspects of Selective Coordination when approaching a project from the very beginning. Decisions made by the engineer regarding Selective Coordination will have influence on project cost, project timeline, robustness of the electrical equipment, and safety of personnel working near or on the electrical equipment. The main objectives of this report are to convey an understanding of the following: recent changes in requirements for Selective Coordination, implications of short-circuit analysis, impacts of selectively coordinated systems on Arc Flash Energy, risks surrounding Arc Flash Hazards, and design processes regarding Selective Coordination.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Electrical and Computer Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Harvey, Tasha
Advisor dc:description.advisor
  • Medhat M. Morcos

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/13327

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Harvey, Tasha. Selective coordination for overcurrent protective devices: applications for buildings in the United States. Masters thesis, Kansas State University, 2012. https://hdl.handle.net/2097/13327