There are many different environmental sampling methods that are currently used in the industry. They include swab, sponge, flocked swab, direct agar contact, and M-Vac. Several studies have been conducted to determine the benefits and drawbacks of each method. Sampling methods utilized in this study were the swab, flocked swab, and M-Vac. Three surfaces were utilized in this study: ultra high density polypropylene, 304 stainless steel with a 2B finish, and 304 stainless steel with a 2B finish and a buffed surface. Surfaces sampled were 100 cm2. Prior to inoculation, surfaces were autoclaved for 15 min at 121 °C for sterilization. Surfaces were inoculated by either Listeria monocytogenes or Escherichia coli O157:H7 at a concentration of 9 log10 CFU/ml by painting the inoculum onto the surface with a sterilized paintbrush. Brushes were dipped in inoculum for 2 sec before painting from left to right once and then from up to down once. Brushes were redipped for 2 sec and the painting step was repeated. The same brush was used for all E. coli O157:H7 samples and a different brush was used for all L. monocytogenes samples. Then, the surfaces were allowed to dry for 30 min before sampling took place. Listeria monocytogenes samples were appropriately diluted and plated in duplicate onto Tryptic Soy Agar (TSA) and Modified Oxford Media (MOX). Escherichia coli O157:H7 samples were properly diluted and plated in duplicate onto TSA and MacConkey Sorbital Agar (MSA). After plating, dry surfaces were stained using LIVE/DEAD® BacLight™ Bacterial Viability Kit. The Zeiss LSM 5 Pascal confocal laser scanning electron microscope was used for microscopy images and photographs. Six 1 mm by 1 mm random and representative images were taken of each surface. Viable cell count results show that the sponge sampling method, in general, recovered a higher number of microorganisms. The swab was normally shown to recover the least number of microorganisms. When examining the microscopy images it can be concluded that biofilms are more easily formed with L. monocytogenes than E. coli O157:H7. Imaging also allowed for a visual representation of the remaining organisms that made it appear as if there was actually more bacteria recovery when the M-Vac sampling method was employed than when the sponge method was utilized.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Food Science Institute
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • DeGeer, Staci Lynn
Advisor dc:description.advisor
  • Daniel Y.C. Fung

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/1350

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

DeGeer, Staci Lynn. Evaluation of four different surface sampling techniques for microbes on three different food preparation surfaces. Masters thesis, Kansas State University, 2009. https://hdl.handle.net/2097/1350