Abstract

dc:description.abstract

Wind pressures affect buildings of all shapes and sizes. Standards and codes have been published that instruct engineers and designers how to account for the wind loads interacting with structures. As further research on wind interaction with buildings is completed, more provisions and requirements are added to the codes and standards. At what point do the provision modifications and additions become more complicated than they need to be for a safe, effective building design? This report evaluates the progression of wind provisions through codes and standards since the early 1900’s. Then a detailed review of the current ASCE 7-05 Analytical Procedure design provisions is completed. Specifically, this report focuses on mid-rise structures 60 feet to 180 feet in height, located in the Midwest region of the United States. Following this in depth review of the ASCE 7 Standard, two studies are carried out. The studies were developed in order to assess the following two ideas: Have the wind load provisions become too complicated? Should there be a simplified procedure for mid-rise buildings?

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Architectural Engineering and Construction Science
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Morgan, Jessica L.
Advisor dc:description.advisor
  • Kimberly W. Kramer

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/1513

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Morgan, Jessica L.. Have wind design provisions become too complicated? a look at the progression of design provisions for mid-rise buildings. Masters thesis, Kansas State University, 2009. https://hdl.handle.net/2097/1513