Back to search

Kansas State University

Un-tensioned pullout tests to predict the bond quality of different prestressing reinforcements used in concrete railroad ties

Abstract

dc:description.abstract

An experimental testing program was conducted at Kansas State University (KSU) to test the bond characteristics of various 5.32-mm-diameter steel wires and smaller diameter (less than 0.5 in.) strands used in prestressed concrete railroad ties. A total of 13 wires and six strands produced by seven different steel manufacturers were used during this testing. Since no wire bond pullout test currently exists, one was developed and its validity tested. This un-tensioned pullout test could serve as a quality control test similar to the standard test for strand bond (ASTM A1081) that has been developed for pretensioned strands. This strand test is currently not verified for strands less than 0.5-in. in diameter, so the procedure was also scrutinized using strands common in the concrete railroad tie industry. Some of the wires and strands contained surface indentations. It is generally accepted that indentations in the reinforcements improve the bond between the steel and concrete. To further complicate the issue, reinforcements with different surface conditions (rust, oils, lubricants) are allowed to be used in the concrete ties which further affects the bond quality of the reinforcements. However, no standardized indentation patterns (shape, size, depth of indent, etc.) or surface conditions (degree of rusting, amount of surface lubricants, etc.) are utilized by all wire and strand manufacturers. Thus, the corresponding bond behavior of these different reinforcements when placed in various concrete mixtures, in terms of average transfer lengths and typical variations, is essentially unknown. The purpose of this testing program was to develop (in the case of wires) or verify/develop (in the case of strands) a pullout testing procedure predictive of the reinforcement’s bond performance in a prestressed application. The test should be relatively inexpensive, demonstrably repeatable, and easily reproducible. Results from the un-tensioned pullout tests were compared to transfer length measurements from accompanying pretensioned concrete prisms in the lab. Additionally, pullout tests and transfer length measurements were obtained at an actual concrete railroad tie manufacturing plant. The obtained data was compared to the lab data and analyzed to further understand the relationship between un-tensioned pullout tests and pretensioned concrete members.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Civil Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Arnold, Matthew Lukas
Advisor dc:description.advisor
  • Robert J. Peterman

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/15625

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Arnold, Matthew Lukas. Un-tensioned pullout tests to predict the bond quality of different prestressing reinforcements used in concrete railroad ties. Masters thesis, Kansas State University, 2013. https://hdl.handle.net/2097/15625