Back to search

Kansas State University

Comparison of arthroscopic lavage, needle lavage, and lavage volume on the recovery of colored microspheres from the tarsocrural joint of the horse

Abstract

dc:description.abstract

Objectives: To quantify recovery of colored microspheres from cadaver tarsocrural joints via arthroscopic or needle lavage, and to compare recovery for 1-5L of lavage fluid. Study design: Randomized experimental trial. Methods: 8 adult Quarter Horse cadavers had 1.5 million 15μm, colored microspheres injected into each tarsocrural joint. Each joint was randomly assigned to receive lavage with an arthroscope and egress cannula (group A) or three (1 ingress, 2 egress) 14 gauge needles (group N) with 5L 0.9% NaCl. The egress fluid from each liter of lavage was collected separately, and the number of microspheres present in each recovered liter was determined via spectrophotometry. Results: A significant interaction (p<0.01) was present between treatment group and liter. The number of microspheres recovered in the first liter of lavage fluid was significantly higher in the needle group than in the arthroscope group (p<0.01). For both groups the number of microspheres recovered in the first liter of lavage fluid represented a majority of the total microspheres collected, and was significantly different from the subsequent liters collected (p<0.01). The number of microspheres recovered did not differ between liters 2, 3, 4, and 5, within or between treatment groups. Conclusions: In this model, tarsocrural lavage with three 14-gauge needles was more effective at removing colored microspheres from the joint than arthroscopic lavage, suggesting the number or placement of portals present may be more important than portal size and flow rate. No difference in microsphere recovery was seen with lavage volumes greater than 1L.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Clinical Sciences
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Loftin, Patrick Glenn
Advisor dc:description.advisor
  • Warren L. Beard

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/19001

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Loftin, Patrick Glenn. Comparison of arthroscopic lavage, needle lavage, and lavage volume on the recovery of colored microspheres from the tarsocrural joint of the horse. Masters thesis, Kansas State University, 2015. https://hdl.handle.net/2097/19001