Back to search

Kansas State University

Characterization of high efficiency neutron detector linear arrays

Abstract

dc:description.abstract

Two types of high efficiency neutron detector arrays (HENDAs), a 32-channel planar device and two trenched devices, were constructed at Kansas State University (KSU) and characterized. These HENDAs are prototypes for a detector that will be developed for the Spallation Neutron Source (SNS), which is located at Oak Ridge National Laboratory (ORNL). The general design objectives of a proposal from the KSU Semiconductor Materials and Radiological Technologies (SMART) Lab to the National Science Foundation, which led to a grant that funded this research, were reached. A spatial resolution for the HENDA prototypes of approximately 120 μm was achieved. The prototypes had relatively fast response times of approximately 1.2 μs, with rise times of 300 ns for the planar device and 200 ns for the 100-μm deep trenched device. The thermal neutron counting efficiency of one of the trenched devices was measured to be about 12%. It is expected that the goal of a 50% efficient HENDA is attainable by making trenches contained within the trenched device deeper and by stacking modules in a sandwich design. The pulse heights produced by the HENDA prototypes were approximately 0.5 volt with noise levels of 13 mvolt, resulting in a signal to noise ratio of almost 40:1. The response of HENDA, when placed in the neutron beam from the tangential beam port of the KSU TRIGA Mark II was proportional to the reactor power from 2 kW to 512 kW. At 512 kW, the neutron flux is φ = 1.08x10[superscript]7 cm[superscript]-2 s[superscript]-1, and therefore HENDA can operate with negligible dead time at neutron fluxes beyond 107 cm-2 s-1. From the experimental results, HENDA is a valuable linear array detector and can be applied to experiments that are designed to study material properties and structures through methods such as neutron diffraction and imaging.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Mechanical and Nuclear Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Henderson, Christopher M. Jr.
Advisor dc:description.advisor
  • William L. Dunn

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/2126

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Henderson, Christopher M. Jr.. Characterization of high efficiency neutron detector linear arrays. Masters thesis, Kansas State University, 2009. https://hdl.handle.net/2097/2126