Back to search

Kansas State University

Effect of concrete properties and prestressing steel indentation types on the development length and flexural capacity of pretensioned concrete members

Abstract

dc:description.abstract

A study was conducted to determine the effect of different concrete properties and prestressing steel indentation types on development length and flexural capacity of pretensioned members. Wires and strands commonly used in the manufacturing of prestressed concrete railroad ties worldwide were selected for the study. Thirteen different 5.32-mm-diameter prestressing wire types and six different strands (four, seven-wire strands and two, three-wire strands) were used to cast prisms with a square cross section. The ratio of concrete to prestressed steel in the test prism’s cross section was representable of typical concrete railroad ties. Thus, geometrical and mechanical properties of test prisms were representative of actual ties in the railroad industry. To understand the effect of concrete-release strengths and slumps on development length, all parameters were kept constant in the prisms except concrete-release strength and slump. To manufacture prisms with different release strengths, all four wires/strands were pulled and detensioned gradually when the concrete compressive strength reached 3500 (24.13 MPa), 4500 (31.03 MPa), and 6000 (41.37 MPa) psi. To determine the effect of different slumps on development length, prisms with different slumps of 3 in. (7.6 cm), 6 in. (15.2 cm), and 9 in. (22.9 cm) were manufactured and all other parameters were kept constant in prisms. All prisms were tested in three-point bending at different spans to obtain estimations of development length based on type of reinforcement, concrete-release strength, and concrete slump. Lastly, a design equation was developed based on experimental data for prediction of development length. In the last phase of load tests, cyclic-loading tests were conducted on the prisms manufactured with wires to evaluate the bond performance of wires with different indentation types under cyclic loading. A total of 210 load tests, including 14 cyclic tests, were conducted. The monotonic-load tests revealed a large difference in the development length of pretensioned concrete members manufactured with different wire/strand types and different concrete-release strengths. Also, the cyclic-load tests revealed a significant difference in bond performance of different wire types under cyclic loading compared to monotonic loading.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Momeni, Amir Farid
Advisor dc:description.advisor
  • Robert J. Peterman

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/32682

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Momeni, Amir Farid. Effect of concrete properties and prestressing steel indentation types on the development length and flexural capacity of pretensioned concrete members. Doctoral thesis, Kansas State University, 2016. https://hdl.handle.net/2097/32682