Back to search

Kansas State University

Design and testing of long-lifetime active sensor arrays for in-core multi-dimensional flux measurements

Abstract

dc:description.abstract

Fission chambers are a common type of detector used to determine the neutron flux and power of a nuclear reactor. Due to the limited space and high neutron flux in a reactor core, it is difficult to perform real-time flux measurements with present-day in-core instrumentation. Micro-pocket fission detectors, or MPFDs, are relatively small in size and have low neutron sensitivity while retaining a large neutron to gamma ray discrimination ratio, thereby, allowing them to be used as active neutron flux monitors inside a nuclear reactor core. The micro-pocket fission chamber allows for multiple detectors to be inserted into a flux port or other available openings within the nuclear reactor core. Any material used to construct the MPFD must be rugged and capable of sustaining radiation damage for long periods of time. Each calibrated MPFD provides measurements of the flux for a discrete location. The size of these detectors allows for a spatial map of the flux to be developed, enabling real-time analysis of core burnup, power peaking, and rod shadowing. Small diameter thermocouples can be included with the array to also measure the temperature at each location. The following document details the research and development of MPFDs for long term use in nuclear power reactors. Previous MPFD designs were improved, miniaturized, and optimized for long term operations in reactor test ports designed for passive measurements of fluence using iron wires. Detector chambers with dimensions of 0.08 in x 0.06 in x 0.04 in were attached to a common cathode and individual anodes to construct an array of the MPFDs. Each array was tested at the Kansas State University TRIGA Mark II nuclear reactor to demonstrate functionality. The linear response in reactor power was measured. These arrays have also demonstrated reactor power tracking by following reactivity changes in steady state operations and reactor pulsing events. Stability testing showed consistent operation at 100 kW for several hours. The MPFDs have been demonstrated to be a viable technology for in-core measurements.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Mechanical and Nuclear Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • George, Tyrel Daniel Frank
Advisor dc:description.advisor
  • Douglas S. McGregor

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/35229

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

George, Tyrel Daniel Frank. Design and testing of long-lifetime active sensor arrays for in-core multi-dimensional flux measurements. Masters thesis, Kansas State University, 2016. https://hdl.handle.net/2097/35229