Back to search

Kansas State University

An investigation of aerogels, foams, and foils for multi-wire proportional counter neutron detectors

Abstract

dc:description.abstract

The 3He gas shortage for neutron detection has caused an increase in research efforts to develop viable alternative technologies. 3He neutron detectors cover areas ranging from 10–1000 cm2 in cylindrical form factors and are ideal for many nuclear applications due to their high intrinsic thermal neutron detection efficiency (> 80%) and gamma-ray discrimination (GRR ≤ 1 x 10-6) capabilities. Neutron monitoring systems for nuclear security applications include Radiation Portal Monitors (RPM’s), backpack, briefcase, and hand-held sensors. A viable replacement technology is presented here and compares three neutron detectors, each with different neutron absorber materials, to current 3He standards. These materials include Li and/or B silica aerogels, LiF impregnated foams, and metallic Li foils. Additionally, other neutron absorbing materials were investigated in this work and include LiF coated Mylar, B foils, BN coated carbon foam, and BN coated plastic honeycomb. From theoretical calculations, the Li foil material showed the greatest promise as a viable 3He alternative, thus a majority of the research efforts were focused on this material. The new neutron detector was a multi-wire proportional counter (MWPC) constructed using alternating banks of anode wires and 95% enriched 6Li foils sheets spaced 1.63 cm apart. In total, six anode banks and five layers of foil were used, thus an anode wire bank was positioned on each side of a suspended foils. Reaction products from the 6Li(n,α)3H reaction were able to escape both side of a foil sheet simultaneously and be measured in the surrounding gas volume concurrently. This new concept of measuring both reaction products from a single neutron absorption in a solid-form absorber material increased the intrinsic thermal neutron detection efficiency and gamma-ray discrimination compared to coated gas-filled detectors. Three different sizes of Li foil MWPC neutron detectors were constructed ranging from 25–1250 cm2 and included detectors for RPM’s, backpacks, and hand-held systems. The measured intrinsic thermal neutron detection efficiency of these devices was approximately 54%, but it is possible to exceed 80% efficiency with additional foils. The gamma-ray discrimination abilities of the detector exceeded 3He tubes by almost three orders of magnitude (GRR = 7.6 x 10-9).

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Department of Mechanical and Nuclear Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nelson, Kyle
Advisor dc:description.advisor
  • Douglas S. McGregor

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/35278

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Nelson, Kyle. An investigation of aerogels, foams, and foils for multi-wire proportional counter neutron detectors. Doctoral thesis, Kansas State University, 2013. https://hdl.handle.net/2097/35278