New energy codes and standards, including ANSI/ASHRAE/IES Standard 90.1: Energy Standard For Buildings Except Low-Rise Residential Buildings (ASHRAE 90.1), LEED and UK Building Regulations Type Part L2 have adopted requirements for electrical sub-metering to be installed within commercial buildings. It is no longer acceptable to only meter total building usage. Separate sub-meters must be installed to monitor where and how power is utilized within commercial buildings. The information provided by the use of these sub-meters can reduce energy usage in the building by informing building owners and occupants of how and where they are using the most energy, by alerting building owners to potential operating and/or maintenance issues and by identifying energy efficiency measures through the use of a building energy audit. This paper identifies the requirements outlined in ASHRAE 90.1, LEED and the UK Building Regulations Part L2. The paper also identifies products and methods to integrate sub-metering into the electrical systems design as well as benefits to separately metering mechanical, electrical and receptacle loads within a building. A case study for a fictitious building is provided, identifying design solutions and costs associated with a sub-metering system meeting the requirements of ASHRAE 90.1.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Architectural Engineering and Construction Science
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Clements, Derek
Advisor dc:description.advisor
  • Fred L. Hasler

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/40365

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Clements, Derek. The impact of sub-metering requirements on building electrical systems design. Masters thesis, Kansas State University, 2020. https://hdl.handle.net/2097/40365