Back to search

Kansas State University

Biomechanical comparison of a less invasive technique and the current accepted technique for arthrodesis of the equine proximal interphalangeal joint

Abstract

dc:description.abstract

Objective - To compare the biomechanical characteristics of the currently recommended (CR) technique and a less invasive (LI) surgical approach for arthrodesis of the proximal interphalangeal joint (PIPJ). Additionally, to describe a technique for cartilage removal and disruption of the subchondral bone. Study design - Randomized paired limb design for biomechanical comparison. Cartilage removal and subchondral bone disruption was accomplished using an orthopedic drill bit. Sample Population – 76 cadaver limbs. Methods - Cadaver PIPJs were drilled using a 3.5mm, 4.5mm or 5.5mm drill bit. Articular surfaces were digitally photographed and analyzed. Other paired PIPJs were arthrodesed using either the CR or the LI surgical technique. Implants consisted of a 3-hole DCP and two 5.5mm transarticular screws. Constructs were tested to failure in dorso-palmar/plantar and latero-medial in single cycle 3-point bending. The maximum load and yield load was measured and composite stiffness was calculated and statistically compared. Results - The LI technique had significantly greater mean yield load (11.3 ± 2.8 kN vs. 7.68 ± 1.1 kN, P=0.008) and mean maximum load (13.5 ± 3.1 kN vs. 10.1 ± 1.94 kN, P= 0.02) under latero-medial bending. Under dorso-palmar/plantar bending there was no statistical difference between the surgical approaches (P=0.5). The 4.5mm drill bit removed 42% ± 7.3 of the cartilage and disrupted subchondral bone. The LI technique had a decreased surgical time (19 ± 3 min.) when compared with the CR (31 ± 3 min.) technique. Conclusion – The LI technique results in a stronger composite as measured in 3-point bending, loaded to failure. Clinical Relevance – The LI surgical technique may be considered for clinical cases requiring arthrodesis of the PIPJ as there is no reduction in composite strength.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Clinical Sciences
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bras, Jose J.
Advisor dc:description.advisor
  • James D. Lillich

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/4252

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Bras, Jose J.. Biomechanical comparison of a less invasive technique and the current accepted technique for arthrodesis of the equine proximal interphalangeal joint. Masters thesis, Kansas State University, 2010. https://hdl.handle.net/2097/4252