Back to search

Kansas State University

Axial twisting within an ending loop of a continuous suture pattern affects the biomechanical properties of knots of certain suture sizes and types

Abstract

dc:description.abstract

Objective: To determine whether axial twisting within an ending loop of a continuous suture pattern negatively impacts security and maximum load to failure of suture knots. Samples: 525 knots (15 samples each of seven different suture types/sizes tested in five knot twist configurations each). Procedures: Each suture type and size were used to create a starting square knot and each of the following ending square knot configurations: 0 twists, 1 twist, 4 twists, and 10 twists. Each suture was tested to maximum failure using an Instron Universal Testing Machine with a 100 kg load cell at a speed of 100 mm/min. Each suture and knot was evaluated for mode of failure using gross evaluation of the knots and video footage recorded during testing. Results: Maximum load to failure was decreased in knots tied within ending loops containing more twists for some types and sizes of suture. All knots with 4-twists made using 0-PDO, 1 PDO, and 2-0 Nylon were more likely to fail at the knot than knots without twists. All knots containing 10 twists, except 3-0 Monoderm, were more likely to fail at the knot than knots without twists. Clinical Relevance: This study shows that for select suture types and sizes, increasing the number of twists present within the ending loop weakens the knot. Ideally the ending loop should be unraveled prior to tying the knot.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Clinical Sciences
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Whyte, MacKenzie
Advisor dc:description.advisor
  • David Upchurch

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/43458

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Whyte, MacKenzie. Axial twisting within an ending loop of a continuous suture pattern affects the biomechanical properties of knots of certain suture sizes and types. Masters thesis, Kansas State University, 2023. https://hdl.handle.net/2097/43458