Back to search

Kansas State University

Evaluation of indented prestressing wires for KDOT bridge members

Abstract

dc:description.abstract

This paper presents the evaluation of indented prestressing wires for Kansas Department of Transportation’s (KDOT) bridge members. This evaluation contains the review of KDOT’s current design practice with prestressed concrete members, the development of alternate member designs utilizing indented prestressing wires, the development of a test plan, the determination of the transfer lengths, loading the specimens to failure, and analysis of the data collected. This purpose of this research was to investigate opportunities to utilize indented prestressing wires in KDOT bridge members to optimize designs to be more efficient while upholding safety standards. Due to the proven shorter development lengths of indented wires in comparison to 7-wire strands of similar sizes, the member selected that had the highest opportunity to showcase the advantages of this was the prestressed deck panel. For this research, six prestressed panels were created using three differing prestressing tendons: 3/8” 7-wire strand, 8 mm T4 European style indented wire, and an 8 mm T2 European style indented wire. Each prestressing tendon had two panels that were created, a 3” by 24” by 72” panel, and a 3” by 24” by 96” panel. After casting, the transfer lengths were determined and a 5 1/2” cast-in-place concrete topping was placed on top of the panels. The panels were then loaded to their ultimate experimental moment-carrying capacity using three-point loading. The data collected was then compared to each respective theoretical value, and to each other. The indented prestressing wires were stronger for the six-foot panel, while having a less area of steel and prestressing force. The 7-wire strand was stronger for the eight-foot panel, due to the wire being fully developed, with the indented prestressing wires being close behind. All panels broke above AASHTO strength recommendations, giving another viable prestressing tendon that KDOT can utilize in their prestressed deck panels.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Civil Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bogner, Derek M.
Advisor dc:description.advisor
  • Robert J. Peterman

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/43549

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Bogner, Derek M.. Evaluation of indented prestressing wires for KDOT bridge members. Masters thesis, Kansas State University, 2023. https://hdl.handle.net/2097/43549