Back to search

Kansas State University

Thermal energy storage design for emergency cooling

Abstract

dc:description.abstract

Emergency cooling systems are applied to any application where the loss of cooling results in damage to the product, loss of data, or equipment failure. Facilities using chilled water for cooling that experience an electrical power outage, even a small one, would cause the chiller to shut down for 20 minutes or more. If emergency cooling is not available, temperatures would continue to increase to dangerous levels, potentially damaging the facility. Examples of facilities that could be protected by having emergency cooling systems are data centers, hospitals, banks, control rooms, laboratories, clean rooms, and emergency shelters among others. This project addresses the current lack of information and methods needed to correctly design emergency cooling systems. Three application uses were investigated for the possible benefits of having emergency cooling systems. The software TRNSYS was used to simulate five typical emergency cooling systems for each of the three applications. The characteristics and differences of the systems developed from the simulations were then analyzed and documented. The five systems simulated include a pressurized chilled water tank (parallel), atmospheric chilled water tank (parallel and series), low temperature chilled water tank (parallel), and ice storage tank (series). Simulations showed that low temperature chilled water tanks were less stratified than regular chilled water tanks by approximately 10%. Simulations also showed that the differences between atmospheric and pressurized tanks were negligible. Each tank discharged energy in the same manner and managed to replenish itself in the same amount of time. Examination of the different system configurations showed that tanks in series with the thermal load have issues with recharging due to its inability to isolate itself from the thermal load. It was also observed that while low temperature chilled water and ice storage tanks had the potential of reducing the storage tank volume, the amount of time ragged cooling will last is decreased by at least a factor of two. The examination of the five systems produced the desired design methodologies needed to address the lack of information on emergency cooling systems. With the reported information designers can effectively engineer systems to meet their needs.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Mechanical and Nuclear Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Basgall, Lance Edgar
Advisor dc:description.advisor
  • Donald L. Fenton

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/4637

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Basgall, Lance Edgar. Thermal energy storage design for emergency cooling. Masters thesis, Kansas State University, 2010. https://hdl.handle.net/2097/4637