Back to search

Kansas State University

Engineering evaluation of an embedded computer-vision system for static dimensional screening of cartridge-case overall length

Abstract

dc:description.abstract

This thesis evaluated CaseMetrology, an embedded computer-vision system developed for static dimensional measurement of cartridge-case overall length (OAL). The formal study was limited to overall length and used a frozen cohort of 60 specimens, an independent manual reference process, and three independently randomized computer-vision placements per specimen for each prospective system configuration. The original V1 configuration used a principal component analysis (PCA) based estimator and established the prospective baseline. It achieved 100 percent measurement availability but met only one of six quantitative performance criteria. Its ninety-fifth percentile pairwise repositioning difference was 0.004831 inch, indicating substantial presentation-dependent variability. Subsequent engineering work investigated acquisition stability, fixture behavior, estimator design, and physical presentation. The final V3 configuration combined controlled specimen presentation with a frozen Endface-Hybrid estimator and was prospectively evaluated after configuration freeze. V3 again achieved 100 percent availability. At the specimen level, mean bias was negative 0.000435 inch, mean absolute error was 0.001517 inch, root mean squared error was 0.001794 inch, the nearest-rank ninety-fifth percentile absolute error was 0.003170 inch, and the maximum absolute error was 0.003913 inch. The ninety-fifth percentile pairwise repositioning difference was 0.000633 inch. This approximately 86.9 percent V1-to-V3 reduction reflects changes in both the estimator and physical presentation, so it cannot be attributed to presentation alone. V3 met five of the six retained quantitative criteria. The only unmet criterion was the ninety-fifth percentile absolute error target of 0.0030 inch. Under the unguarded specification rule, V3 produced one false pass and three false fails. The results demonstrate that repeated presentation stability and absolute agreement with the manual reference were distinct properties of the measurement system. The large improvement in repositioning did not eliminate residual specimen-level disagreement near the specification boundaries. A post-validation guard-band analysis showed that guarded decision logic could reduce observed false pass behavior within the study cohort, but those findings were retrospective and were not validated as a production decision rule. The completed research supports further development of CaseMetrology as a controlled static dimensional screening architecture. It does not establish the prototype as a replacement for precision reference metrology, a production-ready inline inspection system, or an unconditional final-acceptance device across the full specification interval.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
College of Technology and Aviation
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bell, Timmy
Advisor dc:description.advisor
  • Michael J. Pritchard

Subjects

dc:subject × 2

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/47516

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Bell, Timmy. Engineering evaluation of an embedded computer-vision system for static dimensional screening of cartridge-case overall length. Masters thesis, 2026. https://hdl.handle.net/2097/47516