Back to search

Kansas State University

Minimizing the number of collectors to measure uniformity from center pivot systems

Abstract

dc:description.abstract

This report presents the methods to determine the minimum number of collectors to accurately measure the coefficient of uniformity and the average depth of applied water from fixed plate and moving plate center pivot sprinkler irrigation systems. This research conducted an uniformity analysis and an average depth analysis. In the uniformity analysis, catch can collected data from center pivot system tests were divided into base sets of 60 data points. Each base set was further divided into subsets of 30 data points each. T-tests were used to compare the CU values from the base data sets with CU values from each of the subsets. In the average depth analysis, center pivot system catch can data were divided into base sets with 20 data points. Each base data set was divided into 19 subsets. The 1st subset was generated by removing an exterior data point from the base set which was identified by number 1. The 2nd subset was generated by removing other exterior data point (identified by number 20) from the previously generated subset (1st subset). In this manner, a total of 19 subsets for each base set were generated by removing an exterior point from each previous subset. The percent difference (change) in average depth of each subset from the value of the average depth of the base set was calculated. The percent difference in average depth was then plotted against the associated number of collectors. Both analyses documented that a decrease in the number of collectors from the original density of collectors is acceptable to determine the uniformity and averaged depth of applied water from center pivot spans. Results from the uniformity analysis demonstrated that 20 collectors were as effective as 60 collectors to quantify the uniformity of a system. The depth analysis showed that 9 to 12 collectors may be needed to measure the average depth of a system (or a portion of a system) to within 5% to 7.5% of the true value.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Biological & Agricultural Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pragada, Siva Ramakrishna
Advisor dc:description.advisor
  • Gary A. Clark

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/903

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Pragada, Siva Ramakrishna. Minimizing the number of collectors to measure uniformity from center pivot systems. Masters thesis, Kansas State University, 2008. https://hdl.handle.net/2097/903