University of Kansas
Experimental Evaluation of the Behavior of Steel-Reinforced High Density Polyethylene (SRHDPE) Pipes
Abstract
dc:description.abstractSteel-Reinforced High Density Polyethylene (SRHDPE) pipes are a new product recently used for buried pipes. This type of pipe has high-strength steel reinforcing ribs wound helically which are covered by corrosion-resistant High Density Polyethylene (HDPE) resin inside and outside. The steel reinforcement adds ring stiffness to the pipe to maintain the cross-section shape during the installation and to support the soil overburden and traffic loading. For this pipe, steel ribs are much stiffer than plastic thus they are expected to carry most of the load. The combination of steel and plastic materials results in a strong and durable material with smooth inner wall. There are various methods for the design of rigid and flexible pipes. American Water Works Association (AWWA) M11 (2004) and ASSHTO Bridge Design Specifications (2007) have separate design procedures for steel and thermoplastic pipes, respectively. However, it is not clear whether any of these procedures for steel and thermoplastic pipes can be used to design an SRHDPE pipe. Moreover, there is no any approved installation or design specification for this type of pipes. In this experimental study various laboratory tests were conducted to evaluate the stiffness, buckling resistance, and long-term creep behavior of the SRHDPE pipes of 24 in. in diameter in air. In addition, a large-scale plate loading tests conducted on the pipe in the ditch condition under a shallow cover in the large geotechnical testing box of 10 ft long x 6.5 ft wide x 6.6 ft high size to evaluate the performance during installation and under the simulated traffic loads. In this study sand was used as a backfill material and AB-3 and sand were used as base courses. Parallel plate tests conducted shows that the pipe meets the minimum stiffness criterion according to the ASTM F2562/F2562M. The deflected shapes of the pipe in parallel plate tests were obtained using the photogrammetry and found to be elliptical. Creep test conducted in air for a month demonstrates that the SRHDPE pipe deformed under a sustained load. The strains and deflections on the pipe were more during the installation of the pipe than those under the static and cyclic (dynamic) loading. The maximum increase in the vertical diameter (i.e., the vertical deflection) of the pipe was found to be 1.14% of the initial pipe diameter during installation. The ratio of the vertical to horizontal deflection of the pipe in the buried condition under loading was higher than that in the parallel plate tests conducted in air. The earth pressure distribution around the pipe, deflections of the pipe, and strains measured on the pipe were less when the test was conducted with the AB-3 base course than those with the sand base course. During both static and cyclic (dynamic) tests, the pipe crown experienced the highest earth pressures and the pipe had the highest strains on inside and outside plastic wall between the ribs at the pipe crown.
Degree
thesis:*- Name thesis:degree_name
- M.S.
- Discipline thesis:degree_discipline
- Civil, Environmental & Architectural Engineering
- Grantor dc:publisher
- University of Kansas
- Year dc:date.issued
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Khatri, Deep Kumar
- Advisor dc:contributor.advisor
-
- Han, Jie
- Committee members dc:contributor.committeemember
-
- Parsons, Robert L
- Misra, Anil
Subjects
dc:subject × 2Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- embargoedAccess
- Copyright held by the author.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Other
- https://www.proquest.com/docview/1020616915