Back to search

University of Kansas

Evaluating Behavior of Laterally Loaded Piles within MSE Walls under Static and Cyclic Loading

Abstract

dc:description.abstract

Pile foundations have been increasingly installed on rocks or compressible soils within mechanically-stabilized earth walls (MSE) to support structural loads. Integral abutment bridges, sound walls, and traffic signs are common examples of structures supported by pile foundations installed within or behind MSE walls. These structures are often subjected to lateral loads resulting from earthquakes, traffic loads, wind loads, and/or thermal expansion and contraction of bridge girders. Typical approaches available to design MSE walls are limited to MSE walls without pile foundations present within reinforced fill. To minimize the interaction between piles and the MSE wall, designers suggested to place the piles at a distance of six to eight times the pile diameter or/and isolate the piles by using corrugated pipes. These suggested designs lead to increasing the cost of projects through increasing the length of bridge spans or the diameter of piles and requiring pile embedment. To investigate the behavior of piles and the performance of the MSE walls under static and cyclic lateral loading, seven reduced-scale model tests of single and group piles within the MSE walls were conducted inside a test box. In the single pile tests, a 75-mm diameter hollow tube as a pile was placed at a distance of 150 or 300 mm behind the wall facing, while in the group pile tests, the piles were only placed at the distance of 150 mm with a 250-mm spacing between the piles. The piles were subjected to static and cyclic lateral loading until failure. Strain gauges, pressure cells, load cells, and displacement transducers were installed in each model to monitor the responses of the wall and the pile(s) during the test. The test results of the single pile under the static lateral loading showed that the lateral capacity of the pile at the distance of two times pile diameter behind the wall facing decreased by 22% as compared with that at four times pile diameter. The results of the model tests were compared with those of the full-scale field tests in terms of the wall deformation. Empirical relationships were developed to estimate the maximum wall facing displacements due to laterally loaded piles. Based on the measured data, this study proposed an additional lateral earth pressure distribution on wall facing and a method to estimate the maximum tensile force in the geosynthetic induced by pile movement according to the location of the pile behind the MSE wall. The test results of the group piles showed that the lateral capacity of each pile in the group pile test decreased by approximately 40% as compared with that of the single pile, while the wall facing displacements and the strains in the geogrid layer in the group pile test increased. Comparisons were made between the static and cyclic loading tests in term of the lateral pile capacity, the wall facing displacement, the strain in the geogrid, and the lateral earth pressure behind the wall facing at the pile head displacement equal to 20% its diameter. A three-dimensional numerical analysis using the commercial software FLAC 3D 5.01was conducted to evaluate the performance of mechanically-stabilized earth walls (MSE) with piles installed within the reinforced zone subjected to lateral loading. The numerical models were first verified with the available field test results of laterally-loaded piles within MSE walls. A parametric study was conducted to investigate the influence factors on both the MSE walls and the piles, including the location of piles within the MSE wall, the diameter of piles, the stiffness of reinforcement layers, and the reinforcement length ratio. The numerical results showed that the ultimate lateral load capacities of the piles decreased linearly with the decrease of the pile diameter and the pile offset. However, the maximum wall displacement increased with the increase of the pile diameter and the decrease of the pile offset. The increase of reinforcement stiffness had a significant effect on the ultimate lateral load capacity of the piles and a minor effect on the wall facing displacement. The results also showed that the increase of the reinforcement length ratio (L/H) to more than 1.0 had an insignificant effect on the lateral resistance of the piles, the facing displacement of the wall, and the lateral earth pressure behind the MSE wall facing.

Degree

thesis:*
Name thesis:degree_name
D.Eng.
Discipline thesis:degree_discipline
Civil, Environmental & Architectural Engineering
Grantor dc:publisher
University of Kansas
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jawad, Saif
Advisor dc:contributor.advisor
  • Han, Jie
Committee members dc:contributor.committeemember
  • Darabi, Masoud K
  • Hui, Rongqing
  • Parsons, Robert L
  • Schrock, Steven D

Subjects

dc:subject × 1

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • embargoedAccess
  • Copyright held by the author.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Kansas
Base URL
kuscholarworks.ku.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Jawad, Saif. Evaluating Behavior of Laterally Loaded Piles within MSE Walls under Static and Cyclic Loading. University of Kansas, 2019. https://hdl.handle.net/1808/37201