Structural Performance of Manufactured Homes in Wind Zones II and III: Evaluation of Critical Load Path Connections

Abstract

dc:description.abstract

Manufactured homes (MHs) are crucial to affordable housing in the United States, housing over 21 million people, yet their vulnerability to hurricane-induced high winds remains a major concern. Despite this recognized vulnerability, there is little to no experimental data on the structural performance of their key vertical load path connections, namely sheathing-to-rafter (STR), roof-to-wall (RTW), and wall-to-floor (WTF) joints. Previous research has primarily focused on anchorage systems only; however, even for these systems, comprehensive post-disaster performance evaluations are lacking, leaving major gaps in understanding how real-world wind events affect MH structural integrity, which is critical for making code changes. Federal standards under HUD 24 CFR Part 3280 govern MH design and construction are outdated, referencing wind load provisions from the 1980s (ANSI/ASCE 7-88), further compounding vulnerabilities. This thesis is presented as a compendium of four interconnected studies, each targeting the evaluation of a distinct component of MH construction: SRT, RTW, WTF and anchorage systems. These studies are under internal review and being prepared for journal submission. Across the first three studies, significant capacity reductions under cyclic loading were identified, as well as shortfalls in strength with connections consistently underperforming relative to modern wind loads (e.g., ASCE/SEI 7-22) demands. Examination of anchorage systems after Hurricane Michael underscored their systemic underperformance relative to HUD-specified displacement and load criteria, highlighting severe discrepancies between theoretical standards and observed behaviors. This research identifies material selection and fastener pattern as key factors affecting MH performance. Staggered patterns in strap connections outperform row patterns, which tend to induce row-splitting failures and reduce capacity. Key recommendations from this thesis include integrating experimentally derived cyclic reduction factors into design codes, revising HUD guidelines to specify staggered configurations, correcting inconsistencies with anchorage systems, and updating regulatory standards to align with contemporary ASCE/SEI 7-22 provisions. Ultimately, this thesis delivers a foundational, experimentally validated framework vital for revising current MH wind performance standards and informs future modeling, full-scale wind-tunnel validations, and retrofit strategies aimed at enhancing MH resilience in hurricane-prone regions.

Degree

thesis:*
Name thesis:degree_name
M.S.
Discipline thesis:degree_discipline
Civil, Environmental & Architectural Engineering
Grantor dc:publisher
University of Kansas
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Marquez Pesantez, Pedro Jose
Advisor dc:contributor.advisor
  • Sutley, Elaina J.
Committee members dc:contributor.committeemember
  • Collins, William
  • Lequesne, Remy D.
ORCID dc:identifier.orcid

Subjects

dc:subject × 7

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • embargoedAccess
  • This item is protected by copyright and unless otherwise specified the copyright of this thesis/dissertation is held by the author.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Kansas
Base URL
kuscholarworks.ku.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Marquez Pesantez, Pedro Jose. Structural Performance of Manufactured Homes in Wind Zones II and III: Evaluation of Critical Load Path Connections. University of Kansas, 2025. https://hdl.handle.net/1808/37894