University of Kansas
Clinically Relevant Biomimetic Bioreactors For Electrical Stimulation of Hard and Soft Tissue Applications
Abstract
dc:description.abstractThe overall aims of this work are twofold: (1) build a biomimetic bioreactor system which isolates electrical stimulation (E-Stim) and mechanical stimulation (M-Stim) and show the viability of the design setup for future metabolic studies; and (2) develop an electrically active hernia repair mesh (HRM) and test the viability of the E-Stim therapy alongside showing migration rates with E-Stim through a scratch assay. Both early-stage products presented in these aims build off the need in Tissue Engineering (TE) for a robust recapitulation of the physiological environment for clinical applications. The first study focuses on a specific spinal fusion interbody device research question where the second and third studies investigate the viability and migration rates for soft tissue applications. The bioreactor work stemmed from early ovine studies investigating a spinal fusion interbody device that showed preclinical success. The interbody device combined E-Stim with M-Stim for a mechanically synced electrical stimulation (MSES) where every stride powered the novel device with spinal compression. To be able to investigate this phenomenon further, a biomimetic bioreactor that could supply physiological mechanical loads coupled with a function generator supplying E-Stim was proposed and manufactured. The first study presented in this work is the initial verification methodologies of the biomimetic bioreactor in the form of viability assays. The electrically active HRM product concept has the potential to help mitigate the risk of hernia recurrences for many patients. During the second study of this body of work, the preliminary product idea shows initial viability through an ultrasound intensity viability study. Then, the temporal viability studies examine the viability of the E-Stim therapy over the course of 5 and 7 days. Finally, the third study explores the migration rates of NIH 3T3 mouse fibroblast cells and mesenchymal fibrochondrocytes to determine the effects of E-Stim through a scratch assay. The presented work on the bioreactor illustrates cellular viability with minimal cytotoxicity of each stimulation type highlighting E-Stim, M-Stim, and mechanically coupled electrical stimulation (MCES). The main motivation for this work is to set up the ability to further explore specific stimulation types and their role in bone healing. The presented work surrounding the electrically active HRM, demonstrates cellular viability with minimal cytotoxicity and an increased cellular density in the E-Stim groups. The migration rate studies investigate the potential for faster initial wound closure. The main motivation for the electrically active hernia repair work surrounds a clinical need for better healing after hernia repair surgery.
Degree
thesis:*- Name thesis:degree_name
- Ph.D.
- Discipline thesis:degree_discipline
- Bioengineering
- Grantor dc:publisher
- University of Kansas
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Drapal, Victoria Anne
- Advisor dc:contributor.advisor
-
- Friis, Elizabeth A.
- Committee members dc:contributor.committeemember
-
- Tamerler, Candan
- Robinson, Jennifer L.
- Berbel, German
- Dhar, Prajnaparamita
Subjects
dc:subject × 6Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- embargoedAccess
- This item is protected by copyright and unless otherwise specified the copyright of this thesis/dissertation is held by the author.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Other
- https://www.proquest.com/LegacyDocView/DISSNUM/30570948