Modeling and Simulating the Thermal Performance and Energy Consumption of an Occupied Government Administration Building Outfitted with Ceiling Tile Phase Change Materials
Abstract
dc:description.abstractExperimental and numerical studies have shown that buildings with envelope-integrated phase change materials (PCM) have reduced energy use. Most of these studies incorporated PCM into the building envelope in various ways, such as gypsum boards and insulation. Specifically, this dissertation explores the integration of PCM via tiles in drop-ceiling systems using Temploc™ PCM 22°C and Temploc™ PCM 25°C, referred to as “PCM 22°C ceiling tile” or “PCM 22°C tile” and “PCM 25°C ceiling tile” or “PCM 25°C tile,” respectively. The 22°C and 25°C refer to the PCM transition temperature. This dissertation also examines the thermal performance and heating, ventilating, and air conditioning (HVAC) system energy reduction in such PCM-outfitted buildings through experiments and computer simulations. The case study is the City Hall building in Wellington, Kansas, which is an old and occupied building with 734 m^2 of conditioned space, 3.05 m floor-to-ceiling height, and a 2.8 m depth plenum above the ceilings. Data on conditioned space, ceiling temperatures, HVAC electricity, and natural gas were collected for pre- and post-retrofit analyses. An energy simulation model was developed using EnergyPlus™ and validated using the experimental data. The calibrated energy model represented the baseline that was used to evaluate the performance of the PCM-retrofitted building in the absence of a control case. In addition to existing conditions, several other strategies were simulated, such as thermostat cooling and heating setbacks, and forced convection on the ceilings. The results showed that the PCM 22°C tiles could reduce space cooling and heating energy up to 7.0% and 2.0%, respectively, without combining the PCM technology with other strategies. The results also showed that the PCM ceiling tiles were more effective during the cooling than during the heating season. Furthermore, complete phase change cycles throughout the summer were not observed under the PCM tile setup, which may have resulted in lower-than-expected energy savings. Simulations of a strategy that added forced convection with convection coefficients of 1.5-10 W/m^2.K , which corresponded to airflow through ceiling fans, and four hours of 18.8° pre-cooling, showed the PCM within the PCM 22°C tiles still did not solidify. The calibrated model was run for three other U.S. climate zones, which include: 1A (Miami, FL), 3B (Las Vegas, NV), and 6A (Minneapolis, MN). The results showed that the PCM 22°C ceiling tiles contributed to higher space cooling energy reduction than the PCM 25°C ceiling tiles in all climate zones, up to 7% for Minneapolis, MN. In contrast, the PCM 25°C ceiling tiles performed better in space heating energy reduction by 11% for Las Vegas, NV. A sensitivity analysis of the plenum depth revealed an insignificant space-cooling energy difference. However, in addition to more than 21% space heating energy reduction with a 1 m plenum depth, PCM retrofitted ceilings could save up to 4% more space heating energy compared to the existing 2.8 m plenum, e.g., for Las Vegas, NV.
Degree
thesis:*- Name thesis:degree_name
- Ph.D.
- Discipline thesis:degree_discipline
- Civil, Environmental & Architectural Engineering
- Grantor dc:publisher
- University of Kansas
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Arjmand Mazidi, Habib
- Advisor dc:contributor.advisor
-
- Medina, Mario MM
- Committee members dc:contributor.committeemember
-
- Barati, Reza RB
- Chang, Jae JC
- Lines, Brian BL
- Parsons, Robert RP
- ORCID dc:identifier.orcid
Subjects
dc:subject × 6Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- embargoedAccess
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Other
- https://www.proquest.com/LegacyDocView/DISSNUM/30566993