University of Kansas
Optimizing Machine Learning for Real-Time fNIRS-Based Prosthetic Control in Upper-Limb Amputees
Abstract
dc:description.abstractFunctional near-infrared spectroscopy (fNIRS) is a non-invasive, portable brain imagingtechnique that measures oxygenated (HbO) and deoxygenated (HbR) hemodynamic responses associated with cortical motor activity. It has emerged as a promising modality for brain- computer interface development due to its spatial resolution, tolerance to movement, and suitability for mobile applications. Despite this promise, significant gaps remain in the literature regarding which machine learning and deep learning models perform best for fNIRS-based motor classification, which preprocessing pipeline configurations are optimal, and how these decisions should be evaluated beyond raw classification accuracy alone. This study addresses those gaps through a large-scale, systematic benchmark of 22 machine learning and deep learning models across 61 preprocessing pipeline configurations for nine-class upper limb motor classification. Nineteen neurotypical healthy adults performed eight upper limb movements and rest while fNIRS data were collected using a 16-source, 15-detector continuous-wave system. Pipeline configuration factors evaluated included train-test split ratio, channel selection, SMOTE oversampling ratio, preprocessing strategy, and validation method. Performance was assessed using accuracy, balanced accuracy, F1 score, sensitivity, Cohen's Kappa, ROC-AUC, overfitting score, inference time, and a composite efficiency score adapted from an Analytic Hierarchy Process-based framework and modified for BCI-relevant model evaluation. All 22 models exceeded chance-level classification across all 61 pipeline configurations, confirming the feasibility of fNIRS-based nine-class motor decoding in a controlled laboratory setting. Within the highest-performing pipeline configuration, which utilized a 70-30 train-test split, full channel coverage, 1.0 SMOTE oversampling, and bandpass filtering with principal component analysis, the top five models achieved mean accuracies between 94.1% and 95.6% and balanced accuracies between 92.5% and 94.2%, each substantially exceeding the nine-class chance level of 11.1%. Random Forest achieved the highest classification accuracy, while XGBoost emerged as the strongest candidate for future translational BCI development when inference speed, overfitting resistance, and cross-subject consistency were incorporated into the composite efficiency framework. Pipeline configuration significantly influenced performance, and high Kendall's W values confirmed that these effects were highly consistent across participants. The contralateral hemisphere channel configuration retained 91.9% mean accuracy at approximately half the channel count of the full montage, establishing it as a viable reduced- hardware alternative for future BCI system design. The M1, and PMC configurations retained 86.0% and 86.9% mean accuracies, and 85.9% and 86.6% balanced accuracies, respectively suggesting they may also be candidates for future BCI design and development exploration. These findings underscore the importance of multi-metric evaluation frameworks in fNIRS BCI research, and provide a reproducible, standardized benchmark to guide model selection and pipeline design in future upper limb motor classification studies.
Degree
thesis:*- Name thesis:degree_name
- M.S.
- Discipline thesis:degree_discipline
- Bioengineering
- Grantor dc:publisher
- University of Kansas
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bland, Ashley
- Advisor dc:contributor.advisor
-
- Borrell, Jordan
- Committee members dc:contributor.committeemember
-
- Brumberg, Jonathan
- Wilson, Sara
- ORCID dc:identifier.orcid
Subjects
dc:subject × 6Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- openAccess
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Other
- https://www.proquest.com/LegacyDocView/DISSNUM/32700213