Back to search

University of Kansas

COMPARISON OF BL00D GLUCOSE READINGS USING SEVEN METER STRIP COMBINATIONS WITH LABORATORY SERUM GLUCOSE LEVELS

Abstract

dc:description.abstract

In this study data were collected regarding the accuracy of five currently marketed meters for home use of patient self blood glucose monitoring. Data also were compiled regarding ease of operation of each glucose meter and patient cost and availability of meters and necessary consumables. Fasting blood samples were drawn from patients being seen in the adult and pediatric diabetic clinics at the University of Kansas Regional Diabetes Center at the University of Kansas College of Health Sciences and Hospital. Samples were tested in the hospital laboratory as well as on each meter. Blood glucose {BG) meter readings were correlated with blood glucose readings done in the laboratory and displayed in individual scattergrams for each meter, which depicted the appropriate 15 percent decrease of whole blood glucose values {meter readings) from serum glucose values (meter readings) as a shaded area. Scattergrams showed decreased machine accuracy in upper and lower BG extremes. Whole blood glucose values {meter readings) were converted to serum glucose levels by multiplication by 1.12. Corrected values were compared to laboratory serum values using ANOVA for Repeated Measures and Dunnett's Multiple Comparisons Test at P < 0.01. ANOVA and Dunnett's Multiple Comparisons Test showed that only GlucochekTMn using DextrostixR reagent strips had a statistically significant difference from laboratory values at P < 0.01. This meter recently has been revised and may show changed accuracy readings. Each meter exhibits inherent advantages and disadvantages regarding price, calibration, strip utilization, and ease of operation that must be considered prior to recommendation by health care provider.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jorgensen, Rachel G.

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • openAccess
  • This item is protected by copyright and unless otherwise specified the copyright of this thesis/dissertation is held by the author.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1808/39755

Chain of custody

source
Harvested from
University of Kansas
Base URL
kuscholarworks.ku.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Jorgensen, Rachel G.. COMPARISON OF BL00D GLUCOSE READINGS USING SEVEN METER STRIP COMBINATIONS WITH LABORATORY SERUM GLUCOSE LEVELS. 1985. https://hdl.handle.net/1808/39755