University of Kansas
EXPERIMENTAL MEASUREMENT AND UNIFIED ANALYSIS OF THE PHASE EQUILIBRIA AND LIQUID DENSITIES FOR THE SYSTEM 1,3-BUTADIENE -ACETONITRILE AT 305 AND 330 K
Abstract
dc:description.abstract1,3-Butadiene and acetonitrile form a highly non-ideal, industrially important system for which limited reliable data are available in the literature. Traditional approaches for correlating such non-ideal phase equilibria involve non-unified, inconsistent sets of equations. Recent advances in mixing rules for equations of state have shown promise for an alternative, unified approach using an equation of state. The objective of this work was 1) to experimentally determine the molar volumes and phase equilibria for the butadiene -acetonitrile system; and 2) to evaluate the new mixing rules as represented by the Mathias and Copeman equation of state (MC-EDS) for application to such non-ideal systems. A reliable data base consisting of pure component vapor pressure and molar volume data for butadiene and acetonitrile in the temperature range from 300 to 335 K, and mixture total pressure data at 305 and 330 K, was established. The precision of the vapor pressure data is 0. 1 kPa for butadiene and 0.02 kPa for acetonitrile~ based on repeatability. The precision of the molar volume data is 0.00003 1/gmole for both. The precision of the mixture total pressure data is 0.1 kPa. The unified approach using the MC-EDS was unsuccessful for polar non-polar systems~ as represented by butadiene and acetonitrile~ due to the equation's inability to simultaneously predict vapor pressure and molar volume data. The butadiene vapor pressures are described to within the experimental error by the MC~EDS and by the Miller equation~ with the Miller description slightly better. The acetonitrile vapor pressures are also described within experimental error by both equations, with the MC-EDS better. The butadiene molar volume data were fit to within the experimental error by both the MC-EDS and Hankinson and Thomson equation~ with no statistical difference between the two. However~ the MC-EDS is not capable of describing the acetonitrile molar volumes. The Hankinson and Thomson equation describes these data within the experimental error. The MC-EDS provides a better description of the mixture data than the TK-Wilson solution model. However, the MC-EDS parameters are temperature and/or pressure dependent. The TK-Wilson equation did not describe the 305 K data to within the experimental error. The two equations predict very different equilibrium phase compositions. Therefore, future work will require equilibrium phase sampling.
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Laird, Dana G.
Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- openAccess
- This item is protected by copyright and unless otherwise specified the copyright of this thesis/dissertation is held by the author.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1808/39772