Back to search

University of Kansas

Comparisons of Two Different Analytical Methodologies for the Characterization of Sub-Visible Particles in Therapeutic Protein Formulations

Abstract

dc:description.abstract

The US and EU pharmacopeias require sub-visible particle (SbVP) testing of parenteral drug products by either light obscuration (LO) or light microscopy. According to the USP/EP, the LO method requires the use of four measurements consuming a total volume of 25 ml per sample. This large sample volume makes the compendia test not only cost-intensive for biopharmaceutics, but in certain cases impractical, especially in early stage development when clinical supplies are often limited. The first part of this work therefore presents a set of experimental data for evaluation of a small scale, lower volume LO method (1.2 ml per sample). Limitations for detecting various translucent particles such as glass splinters, silicone oil droplets and non-soluble protein aggregates have been considered for both of these LO methods. In addition, a relatively new technology - Micro Flow Digital Imaging (MDI) - has been introduced, which may be a viable add-on to measure SbVP. The purpose of the second phase of this research was to evaluate the advantages and limitations of MDI by directly comparing LO and MDI, and also by comparing two different MDI instruments (i.e., Micro Flow Imaging (MFI) and FlowCam), with regards to subvisible particle counts, size distribution and morphology parameter analysis. As protein subvisible particles vary widely in shape and size, it is difficult to quantitatively describe the limitations of MDI and LO for actual samples of a protein therapeutic drug. Moreover, real-life protein formulations can differ in optical properties such as turbidity, color, refractive index which may potentially influence SbVP detection. During this work, MDI technologies have been improved for the use on a routine basis with protein samples (e.g., FlowCam counting ability was improved by adding a syringe pump for controlled flow, and MFI optical system was enhanced with the so called set-point 3). The effect of solution optical properties on SbVP particle sizing and counting was addressed subsequently using the latest MDI instrument and three different LO instruments. In addition, translucent particles such as glass and irregular shaped particles in development as "false protein standard" (to mimic properties of real life proteinaceous particles) were evaluated in this work.

Degree

thesis:*
Name thesis:degree_name
M.S.
Discipline thesis:degree_discipline
Pharmaceutical Chemistry
Grantor dc:publisher
University of Kansas
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Frommknecht, Tobias
Advisor dc:contributor.advisor
  • Volkin, David B
Committee members dc:contributor.committeemember
  • Volkin, David B.
  • Lunte, Susan M.
  • Mahler, Hanns-Christian

Subjects

dc:subject × 6

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • openAccess
  • This item is protected by copyright and unless otherwise specified the copyright of this thesis/dissertation is held by the author.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Bibid
7643379

Chain of custody

source
Harvested from
University of Kansas
Base URL
kuscholarworks.ku.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Frommknecht, Tobias. Comparisons of Two Different Analytical Methodologies for the Characterization of Sub-Visible Particles in Therapeutic Protein Formulations. University of Kansas, 2011. https://hdl.handle.net/1808/9784