Lund University (Media-Tryck)
Internal Dose Assessment Following a Postulated Accident at a Tungsten-Target Spallation Source : Modelling and Assessment of Inhaled Radionuclides
Abstract
dc:descriptionThis thesis investigates atmospheric dispersion, internal contamination monitoring, and biokinetic behaviour following inhalation of radionuclides released in a postulated loss-of-coolant accident at the European Spallation Source. The findings provide insight into the factors governing the transport, detection, and dosimetric assessment of inhaled radionuclides, supporting the development of appropriate strategies for internal contamination assessment following accidental releases at high-power accelerator facilities that utilise a tungsten target. Specifically, this thesis addresses the transport and deposition of radioactive aerosols in the nearby urban areas, the feasibility of monitoring internal contamination using whole-body counting and urinary gamma spectrometry, and the influence of the respiratory tract behaviour of ¹⁴⁸Gd, considered in the form of aerosolised Gd₂O₃, on internal dose assessment. ¹⁴⁸Gd was investigated in particular because it was identified by the Swedish Radiation Safety Authority as potentially dominant contributor to the inhalation dose in the postulated accident scenario. Atmospheric dispersion modelling using FLEXPART showed that dry deposition was an important mechanism under the investigated release conditions, with deposition strongly influenced by particle size. A radiometric assessment framework showed that whole-body counting provided lower detectable committed effective doses over longer periods and was less sensitive to biokinetic variations than urinary monitoring, supporting its use for robust assessment of internal contamination. Sensitivity analysis of the ¹⁴⁸Gd biokinetic model showed that respiratory deposition and dissolution parameters were major contributors to uncertainty in predicted internal activity. Experimental studies of aerosolised Gd₂O₃ in simulated lung fluid demonstrated slower dissolution than assumed under the standard ICRP Type M classification, with the observed behaviour approaching that represented by Type S. However, these findings should be interpreted in the context of the experimental conditions. Incorporation of the experimentally derived dissolution parameters resulted in committed effective dose coefficients comparable to those obtained using the ICRP Type S assumption.
Degree
thesis:*- Grantor dc:publisher
- Lund University (Media-Tryck)
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ramljak, Belikse
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- info:eu-repo/semantics/openAccess
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
-
urn:isbn:9789168580197
urn:isbn:9789168580203