Back to search

University of Manitoba

Analysis of the physical factors influencing portal imaging exit dosimetry using Monte Carlo modeling

Abstract

dc:description.abstract

As the use of electronic imaging devices (EPIDs) increases, the emphasis which was initially on geometric verification, is shifting to portal exit dosimetry. In this latter concept, a portal dose image obtained during treatment with an EPID is compared with that calculated during treatment planning. The success of this approach will ultimately depend on a proper understanding of the factors that influence the measurement and calculation of dose distributions in the detector plane. The main objective of this work was to identify and analyze such factors using Monte Carlo methods. Firstly, the spectral characteristics of exit photon beams were studied. It was found that the intensity, energy spectrum, mean and effective energies of the beams are significantly affected by variations in the patient/detector geometry. These changes in the spectral characteristics translated into changes in the exit dose to a metal-phosphor detector. Studies performed with different detectors showed that the exit dose is significantly affected by the design and atomic composition of the detector. Existing dose calculation algorithms will need to be improved if they are to be used to predict the exit dose measured by the high atomic number metal phosphor detector. Interestingly, the effects of an increasing air gap and an increasing field size, and vice versa, were found to be roughly complimentary. This suggests the use of equivalent field size techniques to account for intensity and spectral changes arising from air gap variations. Based on Monte Carlo modeling, an equivalent field size technique has been proposed and confirmed experimentally. An advantage of this approach is that it can be integrated with the existing dose calculation algorithms with only minor modifications.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Physics and Astronomy
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yeboah, Collins

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/1008

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Yeboah, Collins. Analysis of the physical factors influencing portal imaging exit dosimetry using Monte Carlo modeling. Master of Science (M.Sc.) thesis, 1997. http://hdl.handle.net/1993/1008