Back to search

University of Manitoba

Developing an acoustic discharge measurement technique for hydroelectric performance testing

Abstract

dc:description.abstract

The efficient operation of hydroelectric generating plants requires an accurate definition of the performance relationships of each turbine/generator unit. Of the information obtained by performance testing, discharge is the most difficult to measure accurately. It is envisioned that acoustic transit-time velocity measurement technology can be applied at low-head plants to obtain more accurate discharge measurements over current practices. The technique proposed herein involves continuously traversing a number of acoustic paths, each providing a chordal average velocity measurement, across the turbine intake to obtain a complete integration of the complex velocity profile typical of low-head hydroelectric plant conditions. Hydraulic laboratory testing of a single acoustic cell is the focus of this study. The acoustic cell was traversed across a laboratory intake structure to measure discharge; this measurement was compared to known laboratory flowrate to assess the accuracy and repeatability of the proposeddischarge measurement technique. Various continuous sampling strategies (i.e., traverse rates) and discrete sampling strategies (Gauss-Legendre positioning) are evaluated. A number of flow perturbances were also added to the intake structure to evaluate the technique in complex flow conditions. Based on the results described herein, it is concluded that the proposed continuous traversing technique can provide efficient, accurate and repeatable discharge measurements under complex flow conditions relative to discrete sampling techniques. In disturbed flow conditions, testing revealed that discrete sampling strategies were subject to considerable systematic integration error. Further laboratory testing of a multiple cell system is recommended because of the promising results obtained from this study. Also, two key recommendations pertaining to field testing of low-head plants are made: (1) low order discrete sampling techniques should not be practiced; and (2) careful consideration should be devoted to the geometry of the acoustic paths as conflicting effects on accuracy are dependent on the acoustic path lengths and path angles employed.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Civil Engineering
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gawne, Kevin D.

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/1086

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Gawne, Kevin D.. Developing an acoustic discharge measurement technique for hydroelectric performance testing. Master of Science (M.Sc.) thesis, 1997. http://hdl.handle.net/1993/1086