University of Manitoba
Two-phase pressure drop and phase distribution at a reduced horizontal tee junction, the effect of system pressure
Abstract
dc:description.abstractThe present investigation generated phase-distribution and pressure-drop data for air-water flows in a reduced horizontal tee junction. This junction consisted of a 38.1-mm I.D. inlet tube with a 7.85-mm I.D. branch tube, thus yielding a diameter ratio of $\rm D\sb3/D\sb1=0.206.$ The operating conditions were as follows: an inlet* pressure of 3.0 bar (abs), an inlet temperature near ambient, an inlet mass flux in the range \rm 11.5 \le G\sb1\le 181.5 kg/m\sp2s, inlet superficial gas velocities in the range \rm 2.7\le J\sb{G1}\le 40.1 m/s, superficial liquid velocities in the range \rm 0.0021\le J\sb{L1}\le 0.0398 m/s, and extraction ratios in the range $\rm 0.049\le W\sb3/W\sb1\le 0.904.$ This combination of inlet conditions led to observed inlet flow regimes of stratified, stratified-wavy, wavy, semiannular, and annular. The present data were compared against those of Walters (1994) under similar conditions with the exception of system (inlet) pressure. (Abstract shortened by UMI.) ftn*The word "inlet,"as used in this thesis, refers to the tee junction inlet.
Degree
thesis:*- Level thesis:degree_level
- Master of Science (M.Sc.)
- Discipline thesis:degree_discipline
- Mechanical and Manufacturing Engineering
- Year dc:date.issued
- 1998
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Van Gorp, Casey A.
Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1993/1484