Back to search

University of Manitoba

Field testing, modelling and analysis of ferroresonance in a high voltage power system

Abstract

dc:description.abstract

Catastrophic equipment failures continue to occur today due to ferroresonance even though this phenomenon has been extensively studied over the past ninety years. This thesis is concerned with the tasks of defining where ferroresonance problems can exist in a high voltage power system, of determining methods for displaying safety margins between nonferroresonant and ferroresonant operating regions and improving upon existing ferroresonance simulation techniques. Several different ferroresonant circuits have been modelled and compared with field measurements taken on the Manitoba Hydro 230-kV power system or compared with laboratory measurements including: a de-energized transformer connected to the grading capacitance of an open circuit breaker, a transformer-terminated doublecircuit transmission line and a coupling capacitor voltage transformer. In a high voltage power system, the most prevalent ferroresonance circuit occurs between a de-energized transformer and the grading capacitor of an open circuit breaker. Experimental work has shown that losses in a pr ctical transformer are much larger during ferroresonance oscillation modes than predicted by conventional modelling techniques. A simple switched eddy-current loss resistor is found able to model the losses during subharmonic and fundamental frequency ferroresonance in a laboratory transformer. A major contribution of this work is a new method of visualizing the margin between nonferroresonant and ferroresonant states in a transformer/grading capacitor circuit has been developed. A general set of averaged equations is derived that permit the analysis of an nth order polynomial approximation of the magnetization curve. The location of the saddle points and slope of the stable manifold through the saddle points can be determined for a particular transformer under study. The Limacon of Pascal is found to be a good approximation to the geometric shape of the basin of attraction of the period-1 ferroresonant attractor and can be calculated using the saddle point location and slope of the stable manifold. The critical parameters resulting in a crossing of the separatrix can then be found by iteratively solving the Limacon equations. The new method will assist utility engineers in quickly assessing the potential risk of ferroresonance in their power system.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy (Ph.D.)
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jacobson, David

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/1866

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Jacobson, David. Field testing, modelling and analysis of ferroresonance in a high voltage power system. Doctor of Philosophy (Ph.D.) thesis, 2000. http://hdl.handle.net/1993/1866