Back to search

Proc. of SPIE

Inductively Coupled Corrosion Potential Sensor for Remote Passive Monitoring of New and Existing Civil Structures

Abstract

dc:description.abstract

The thesis describes development and optimization process of an inductively coupled coil corrosion potential sensor for long-term civil structure health monitoring remotely. This is of growing interest for decreasing the maintenance cost, reducing the deterioration significantly and increasing the safety. The thesis is organized accordingly introduction, circuit modeling of the sensor, optimization and fabrication of the sensors and the simulated and experimental results from new and existing civil structure. The two geometrical design, cylindrical shape and Printed Circuit Board (PCB) based sensor parts of this research and their encapsulation technique for long-term enduring in harsh and corrosive environment of the civil infrastructure is described in the thesis. Results of an accelerated corrosion test on an embedded cylindrical shaped sensor indicates that the corrosion potential can be monitored with less than 10 mV resolution with a sensor sensitivity of ~0.73 kHz/mV. The last part describes a novel technique for a PCB sensor to simulate the existing structure already contaminated with corrosive substances such as chlorides. Two encapsulation techniques, non-conductive epoxy sealed and PLEXIGLAS with air gap sealed embedded PCB sensors response are compared from the accelerated corrosion test on new and built-in civil structure. Finally, results from the accelerated corrosion tests using the two encapsulation techniques mentioned above demonstrate that the embedded sensor in an existing structure may take up to 60 days to see the significant corrosion with a sensor sensitivity of ~ 1.53 kHz/mV or ~ 1.63 kHz/mV respectively. Since chlorides take many years to diffuse into concrete used for civil structures these sensors will respond fast enough to be used in existing structures as well as in new structures.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
Proc. of SPIE
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • PERVEEN, KHALADA
Advisor dc:contributor.supervisor
  • Thomson, D. J.(Elec. & Comp. Eng.)
Committee members dc:contributor.committeemember
  • Shafai, C. (Elec. & Comp. Eng.)
  • Richards, N. (Mech.& Mfg. Eng.)

Subjects

dc:subject × 3

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
Inductively coupled corrosion potential sensor for steel reinforced concrete with time domain gating interrogation
An embedded inductively coupled printed circuit board based corrosion potential sensor

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

PERVEEN, KHALADA. Inductively Coupled Corrosion Potential Sensor for Remote Passive Monitoring of New and Existing Civil Structures. Master of Science (M.Sc.) thesis, Proc. of SPIE, 2013. http://hdl.handle.net/1993/22728