A study of joint slip in galvanized bolted angle connections

Abstract

dc:description.abstract

A study on joint behavior with a special reference to joint slip of bolted joints in electric transmission line towers was considered beneficial and opportune. The investigation consisted of a literature survey and an experimental study. The latter consisted of: (i) Test Series A, which dealt with a tower leg splice joint loaded in compression and incorporated nine joint tests; (ii) Test Series B, which dealt with a web bracing member joint loaded in tension and incorporated nine joint tests; (iii) Test Series C, which dealt with a joint of low load carrying capacity and high eccentricity loaded in compression and incorporated 36 joint tests; (iv) Test Series D, which dealt with bolt calibration by the turn-of-nut method and included 20 bolt tests; (v) Test Series E, which dealt with direct tension tests of bolts and included nine bolt tests; and (vi) Test Series F, which dealt with tension tests on steel angle sections and included six tensile coupon tests. (Abstract shortened by UMI.)

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Civil Engineering
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ungkurapinan, Nibong

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/2341

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ungkurapinan, Nibong. A study of joint slip in galvanized bolted angle connections. Master of Science (M.Sc.) thesis, 2000. http://hdl.handle.net/1993/2341