Back to search

Medical Physics

in vivo patient dose verification of volumetric modulated arc therapy including stereotactic body radiation treatment applications using portal dose images

Abstract

dc:description.abstract

The complexity of radiation therapy delivery has increased over the years due to advancements in computing and technical innovation. A system of dose delivery verification has the potential to catch treatment errors and therefore improve patient safety. The goal of this thesis was to create a portal image-based in vivo dose reconstruction model for volumetric modulated arc therapy (VMAT) deliveries, specifically for stereotactic body radiation therapy (SBRT). This model-based approach should be robust and feasible within a clinical setting. VMAT involves the modulation of dose rate, gantry speed, and aperture shaping while the treatment gantry (i.e., x-ray beam) rotates about the patient. In this work, portal images were acquired using an amorphous silicon electronic portal imaging device (a-Si EPID). A geometrical characterization of the linear accelerator (linac) during VMAT delivery was performed. An angle adjustment method was determined which improves each EPID’s angular accuracy to within ±1° of the true physical angle. SBRT delivers large doses over fewer fractions than conventional radiotherapy, therefore, any error during an SBRT delivery will have a greater impact on the patient. In this work, a robust, model-based SBRT-VMAT dose reconstruction verification system using EPID images was developed. The model was determined to be clinically feasible. The accuracy of a 3D in vivo dose reconstruction, using all the EPID images acquired during treatment, is sensitive to the chosen frame averaging per EPID image: the greater the frame averaging, the larger the reconstruction error. Optimization of the EPID frame averaging number as a function of average linac gantry speed and dose per fraction were determined. The EPID-based in vivo dose reconstruction model for SBRT-VMAT developed here was determined to be robust, accurate, and clinically feasible as long as adjustments were made in order to correct for EPID image geometrical errors and frame-averaging errors.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy (Ph.D.)
Discipline thesis:degree_discipline
Physics and Astronomy
Grantor dc:publisher
Medical Physics
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • McCowan, Peter Michael
Advisor dc:contributor.supervisor
  • McCurdy, Boyd (Physics & Astronomy)
Committee members dc:contributor.committeemember
  • Rickey, Daniel (Physics and Astronomy)
  • Lewis, John (Physics and Astronomy)
  • Ryner, Lawrence (Physics & Astronomy)
  • Lin, Francis (Physics and Astronomy)
  • Thomas, Gabriel (Electrical and Computer Engineering)

Subjects

dc:subject × 2

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
MLA

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

McCowan, Peter Michael. in vivo patient dose verification of volumetric modulated arc therapy including stereotactic body radiation treatment applications using portal dose images. Doctor of Philosophy (Ph.D.) thesis, Medical Physics, 2015. https://hdl.handle.net/1993/31120