Back to search

University of Manitoba

Two-phase flow and pressure drop in a horizontal, equal-sided combining tee junction

Abstract

dc:description.abstract

A careful review of the literature showed that there is a serious lack of information (experimental or analytical) on the pressure losses during two-phase flow in combining tee junctions. Pipe networks in industrial applications involve combining and dividing junctions and knowledge of the pressure losses at these junctions is essential for analysis of the flow distribution in the network. To this end, the pressure losses of air-water mixtures passing through a horizontal, combining tee junction with a 37.8 mm diameter were experimentally studied with annular, wavy, and slug flow regimes in the outlet. The test matrix independently varied the outlet flow rates, the outlet mixture qualities, the gas distribution between the inlets, and the liquid distribution between the inlets. All experiments were conducted at room temperature and a nominal absolute pressure at the centre of the junction of 150 kPa. The pressure distribution in all three legs of the tee was determined using up to 49 pressure taps distributed among the three sides and monitored using pressure transducers to produce accurate measurements of the pressure losses. Time-averaged pressure measurements with annular and wavy flows are reported, while pressure measurements with slug flows were not repeatable. A new model and empirical coefficients is presented that allows accurate prediction of pressure losses for flows with either an annular or wavy outlet. Time-varying pressure measurements are presented and analyzed using probability density functions. Different distributions were found for differential measurements depending on whether or not slugging was present in the system. The probability density functions for cases with annular or wavy flow in the outlet followed Gaussian distributions, while cases with slug flow had skewed distributions. Time-varying pressure signals showed a time lag between slug events based on pressure tap locations. A visual study with slug flow present in the system showed upstream travelling waves induced in a stratified inlet when slug flow was present in the other, which led to unexpected slugging under certain flow conditions.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy (Ph.D.)
Discipline thesis:degree_discipline
Mechanical Engineering
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Joyce, Gavin D. A.
Advisor dc:contributor.supervisor
  • Soliman, Hassan (Mechanical Engineering)
Committee members dc:contributor.committeemember
  • Tachie, Mark (Mechanical Engineering)
  • Cicek, Nazim (Biosystems Engineering)
  • Ahmed, Wael (University of Guelph)

Subjects

dc:subject × 5

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1993/31659

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Joyce, Gavin D. A.. Two-phase flow and pressure drop in a horizontal, equal-sided combining tee junction. Doctor of Philosophy (Ph.D.) thesis, 2016. https://hdl.handle.net/1993/31659