Back to search

Elsevier

Computational wear simulations in total knee replacements with consideration for energy dissipation and colloid-mediated boundary lubrication

Abstract

dc:description.abstract

The cost and time efficiency of computational wear simulations may enable the optimization of total knee replacements for the reduction of polyethylene wear, thereby potentially improving the long term success of total knee replacements. However, previously existing computational wear models have only demonstrated weak correlations (R2<0.65) in comparison to knee simulator wear tests. This thesis presents the development and verification of new computational models for the simulation of polyethylene wear in total knee replacements. Finite element and multibody dynamic simulation models were implemented for the prediction of total knee replacement contact mechanics. A new wear model was developed, based on a time dependent cross shear and energy dissipation approach, and was evaluated for the prediction of total knee replacement wear. The effects of contact pressure on polyethylene wear were investigated through both computational and in vitro experiments. This verified computational wear model was further advanced through the development and addition of a lubrication model, which provided consideration for the colloidal protein mediated boundary lubrication of total knee replacements. Finally, the predictability of the newly developed computational model was evaluated through the prediction of a broad range of pin-on-disk and knee simulator wear test experiments. The time dependent – energy dissipation – colloidal boundary lubrication model developed in this thesis resulted in greatly improved correlation strength for the prediction of pin-on-disk (R2=0.85) and knee simulator wear test (R2=0.96) results compared with previously published wear models such as Archard’s wear law (R2=0.12), time independent cross shear wear models (R2=0.60) and other time dependent wear models (R2=0.65). The computational wear simulation models developed in this thesis have demonstrated sufficient predictive accuracy (Validation Metric: 0.85) to enable the optimization of total knee replacements for the reduction of wear, which may improve the long term success of these necessary clinical devices.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy (Ph.D.)
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
Elsevier
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • O'Brien, Sean Tyler
Advisor dc:contributor.supervisor
  • Brandt, Jan-M (Mechanical Engineering) Luo, Yunhua (Mechanical Engineering)
Committee members dc:contributor.committeemember
  • Wyss, Urs (Mechanical Engineering)
  • Zhang, Qiang (Biosystems Engineering)
  • Rullkoetter, Paul (University of Denver)

Subjects

dc:subject × 7

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
O’Brien, S., Luo, Y., Brandt, J-M. (2015) In-Vitro and In-Silico Investigations on the Influence of Contact Pressure on Cross-linked Polyethylene Wear in Total Knee Replacements. Wear. 332: 687-693.
O’Brien, S., Bohm, E., Petrak, M., Wyss, U., Brandt, J-M. (2014) An Energy Dissipation and Cross Shear Time Dependent Computational Wear Model for the Analysis of Polyethylene Wear in Total Knee Replacements. Journal of Biomechanics. 47.5: 1127-1133.

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

O'Brien, Sean Tyler. Computational wear simulations in total knee replacements with consideration for energy dissipation and colloid-mediated boundary lubrication. Doctor of Philosophy (Ph.D.) thesis, Elsevier, 2015. https://hdl.handle.net/1993/31663