Back to search

University of Manitoba

Punching shear behaviour of GFRP-RC slab-column edge connections with high strength concrete and shear reinforcement

Abstract

dc:description.abstract

In this thesis the experimental results of seven full-scale glass fiber-reinforced polymer (GFRP) reinforced concrete (RC) slab-column edge connections are presented. The dimensions of the slabs were 2,800×1,550×200 mm with a square column measuring 300×300×2,200 mm. The test connections were divided into two series. Series I included three connections investigating the effect of flexural reinforcement ratio (0.90, 1.35 and 1.80%) when high strength concrete (HSC) is used, while Series II included four connections investigating the effect of GFRP shear reinforcement type and pattern on normal strength concrete (NSC) connections. Test results showed that increasing the reinforcement ratio increased the punching capacity and the post-cracking stiffness of the HSC connections. Furthermore, the use of headed studs and corrugated bars increased the punching capacity and the deformability of the NSC connections. Test results were compared to the predictions of the Canadian and American design provisions for FRP-RC structures.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Civil Engineering
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mostafa, Ahmed
Advisor dc:contributor.supervisor
  • El-Salakawy, Ehab (Civil Engineering)
Committee members dc:contributor.committeemember
  • Shehata, Emile (Civil Engineering)
  • Birouk, Madjid (Mechanical Engineering)

Subjects

dc:subject × 7

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1993/31932

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mostafa, Ahmed. Punching shear behaviour of GFRP-RC slab-column edge connections with high strength concrete and shear reinforcement. Master of Science (M.Sc.) thesis, 2016. https://hdl.handle.net/1993/31932