Back to search

University of Manitoba

Inferring axon diameters using magnetic resonance imaging oscillating gradient spin echo sequences

Abstract

dc:description.abstract

A new diffusion magnetic resonance imaging method was developed and optimized to probe the smallest structures to date (0.54 ± 0.06 µm), micron-sized tissue structures, such as small axon diameters (AxD). This method relies on probing the shortest possible diffusion time scales. Current temporal diffusion spectroscopy methods cannot distinguish small structures because the pulse sequences limit the ability to probe the shortest diffusion times. This method circumvents those limitations using oscillating gradients in lieu of pulsed gradients and will have important neuroscience applications such as probing AxD distributions. The required imaging time will need to be shortened in order for the method to be clinically useful. The thesis presents three sets of experiments that guided the selection of pulse sequence and imaging parameters needed for measuring micron-sized restrictions. Measurements were made on water diffusing between 3 μm polystyrene spheres. The gradient frequencies and amplitudes used were appropriate to infer the pore sizes between the 3 μm beads while the fit results indicated a better signal-to-noise ratio would help make the results more accurate. Measurements made on water diffusing inside various tubes indicated the gradient frequency range was not appropriate for inferences of tube diameters that were 250 μm and larger. The second set of experiments used information from the first set to choose imaging and gradient parameters for measurements of water diffusing between 3, 6, and 10 μm beads and 150 μm tubes. Pore sizes, surface-to-volume ratio and diameters could be inferred from these samples with this method. The results indicated that the method had a resolution limit which is greater than 0.5 μm given that the pore sizes between the 3 μm and 6 μm beads were indistinguishable. The more accurate inferences of diameters of the bead rather than diameters of the tubes suggest the method is better optimized for micron-sized samples rather than 150 μm-sized samples. The final experiment tested the method on human corpus callosum. The results suggest that the resolution limit of the method needs to be decreased and careful attention to the axon direction would be needed. Suggestions for improvements to the model are made.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy (Ph.D.)
Discipline thesis:degree_discipline
Physics and Astronomy
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Herrera, Sheryl Lyn
Advisor dc:contributor.supervisor
  • Martin, Melanie (Physics and Astronomy)
Committee members dc:contributor.committeemember
  • Elhami, Esmat (Physics and Astronomy)
  • Lin, Francis (Physics and Astronomy)
  • Goltz, Douglas (Chemistry)
  • Pagel, Mark David (MD Anderson Cancer Centre, University of Texas)

Subjects

dc:subject × 5

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/33322

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Herrera, Sheryl Lyn. Inferring axon diameters using magnetic resonance imaging oscillating gradient spin echo sequences. Doctor of Philosophy (Ph.D.) thesis, 2018. http://hdl.handle.net/1993/33322