Back to search

University of Manitoba

Evaluation of an integrated sewage pipe with ground heat exchanger for long-term efficiency estimation

Abstract

dc:description.abstract

Extracting heat from a sewage pipe through a typical horizontal ground heat exchanger has recently been introduced as a renewable energy alternative to reduce fossil fuel usage. This paper presents a novel design for a ground heat exchanger that extracts heat from the surrounding soil and sewage within the pipe while simultaneously being carried to a wastewater treatment plant. This research focuses on the long-term efficiency of the system under transient conditions in a cold climate. A numerical model using COMSOL Multiphysics was developed to verify the sustainability of the system for over 25 years. The model used constant inlet fluid temperatures to evaluate heat by conductive and convective heat transfer mechanisms within the pipe and surrounding soils by considering phase change of pore water. The results showed, by adopting the operation strategy proposed in this study, a maximum temperature change in the surrounding soil adjacent to the heat extraction system over 25 years was 0.10°C during the heating season in Winnipeg, Manitoba. The horizontal distance at which the heat extraction system did not show an impact on temperature change of adjacent soil was determined at 4 meters. Critical parameters in this evaluation were system depth, sewage level, and the high-density polyethylene pipe thermal properties. The sustainability of the system was not affected by the system depth due to thermal balancing between climatic, subsurface and sewage heat fluxes. Sustainable behavior was achieved at 50% and 75% of sewage pipe capacity. The effect on thermal performance from the high-density polyethylene pipe thermal properties was deemed insignificant.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Civil Engineering
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dacquay, Connor
Advisor dc:contributor.supervisor
  • Holländer, Hartmut (Civil Engineering) Kavgic, Miroslava (Civil Engineering)
Committee members dc:contributor.committeemember
  • Maghoul, Pooneh (Civil Engineering)
  • Ormiston, Scott (Mechanical Engineering)

Subjects

dc:subject × 3

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1993/34542

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Dacquay, Connor. Evaluation of an integrated sewage pipe with ground heat exchanger for long-term efficiency estimation. Master of Science (M.Sc.) thesis, 2020. https://hdl.handle.net/1993/34542