Back to search

University of Manitoba

Investigation of the effects of humidity and surface charge on partial discharge in insulator posts under DC voltage

Abstract

dc:description.abstract

The flashover mechanism and performance of insulators have always been significant of importance to insulation engineers’ attention. A serious flashover accident will damage insulators and influence the reliability of the whole converter station and result in severe outages. It is believed that the flashover and partial discharge phenomena are strongly related to environmental conditions such as temperature, humidity, pressure, pollution's, and even space charges. The motivation of this thesis was to study the random discharge phenomenon that was observed in a Manitoba Hydro's HVDC substation to avoid further insulation damages. However, the lack of data prevents engineers from making firm conclusions. As such a data acquisition system was proposed that will collect leakage current data flowing in a reactor’s insulation post, to help to build a better understanding of the correlation between PD and environmental influences. The field tests at the HVDC substation studied the behavior of the leakage current from smoothing reactor’s ground wire and its associated electric field changes. Through the field tests, we found that the discharge phenomena exists only under certain weather conditions were. One hypothesis for partial discharge occurring on the insulator stacks is the influences of moisture and static charge. Moisture helps the static charge buildup on the insulator will spread along the insulator surface and create a conducting path between the smoothing reactor, flange, and ground. The sharp edge of the flange within this conducting path will generate corona and cause a discharge problem. For the laboratory experiments, humidity and surface charge studies were implemented in air and on FRP insulators under HVDC in order to get a better understanding of environmental influences on partial discharge behaviors. The results demonstrated that for a given electrode configuration, both humidity and surface charge have significant effects on the behavior of partial discharge. We also noticed that the relationship between total charge magnitude Q and equivalent frequency F followed a curve with exponential decay, and under high humidity environment or with surface charge present, the decay speed was faster than normal conditions. And the lab results also proved that time-frequency-charge (TFQ) mapping technique can be used for HVDC PD identifications.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Deng, Hao Liang
Advisor dc:contributor.supervisor
  • Kordi, Behzad (Electrical and Computer Engineering)
Committee members dc:contributor.committeemember
  • Rajapakse, Athula (Electrical and Computer Engineering)
  • Fernando, Namal (Electrical and Computer Engineering)

Subjects

dc:subject × 2

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
IEEE

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Deng, Hao Liang. Investigation of the effects of humidity and surface charge on partial discharge in insulator posts under DC voltage. Master of Science (M.Sc.) thesis, 2020. http://hdl.handle.net/1993/34569