Back to search

University of Manitoba

Use of Noise Power Spectra (NPS) for quality control in digital radiography

Abstract

dc:description.abstract

Quality control (QC) guidance documents recommend various tests for evaluation of different parameters of x ray imaging systems’ performance. QC tests can be time consuming, user-dependent and require specialized tools. The aim of this thesis is to investigate the noise power spectrum (NPS) as a QC constancy test which is simple, fast and lends itself easily to automated analysis. Uniform images were acquired under different conditions representing deviations from ideal performance using two digital x-ray systems. The stationarity and ergodicity of the noise was assessed. The normalized NPS (NNPS) were calculated using the methodology of the international electrotechnical commission. The total relative difference was used to quantify the changes in the NNPS. The NNPS was computed for images: with focal spot blooming, collected using large and small focal spot (to mimic resolution change), various tube voltage values, with and without defective pixels, with residual image and with a mismatched anti-scatter grid. Results showed that the NPS method is not sensitive to image lag and focal spot blooming investigated in this study. However, the NPS method was sensitive to changes in resolution introduced by changing the focal spot size, kV deviations as small as 1 kV, defective pixels representing 0.01% of the image pixel and 0.98 MSE difference from the original image, affixed pattern artifacts and a mismatched grid. The NPS was decomposed into its components (fixed pattern, quantum and electronic) to investigate the effect of different performance deviations on the NPS components. The negligibility of the electronic noise was verified. The results showed the fixed pattern changes impacted the fixed pattern NPS component the most and the changes associated with quantum noise affected the quantum component. This thesis suggests the NPS is sensitive to a variety of deviations in system parameters and performance metrics likely to arise in the quality control of digital radiography systems. NPS decomposition can further help identify the source of deviations. The NPS has the potential to be used as a constancy test for routine quality control of DR systems.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Physics and Astronomy
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ghorbanzade, Mohadese
Advisor dc:contributor.supervisor
  • Elbakri, Idris (Physics and Astronomy)
Committee members dc:contributor.committeemember
  • Pistorius, Stephen (Physics and Astronomy)
  • Brownlee, Meredith (Oral and Maxillofacial Radiology)

Subjects

dc:subject × 4

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1993/34961

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ghorbanzade, Mohadese. Use of Noise Power Spectra (NPS) for quality control in digital radiography. Master of Science (M.Sc.) thesis, 2020. https://hdl.handle.net/1993/34961