Back to search

University of Manitoba

Developing a tri-hybrid algorithm to predict patient x-ray scatter into planar imaging detectors for therapeutic photon beams

Abstract

dc:description.abstract

In vivo dosimetry via transmission imaging of the therapy beam can verify the intended treatment plan was delivered to the patient. However, the EPID (electronic portal imaging device) transmission images are contaminated with patient-generated scattered photons. If this component can be accurately estimated, its effect can be removed and therefore the resulting in vivo patient dose estimate will be more accurate. This thesis presents the development of a ‘tri-hybrid’ (TH) algorithm to provide accurate estimates of patient-generated photon scatter at the EPID. The TH method combines three approaches: 1) Analytical methods to solve exactly for singly-scattered photon fluence. 2) For multiply scattered photon fluence, a modified hybrid Monte Carlo (MC) simulation method was applied, using only a few thousand histories. From each second and higher-order interaction site in the MC simulation, energy fluence entering all pixels of the EPID scoring plane was calculated using analytical methods. 3) For the bremsstrahlung and positron annihilation component, a convolution/superposition approach was employed using pre-generated pencil beam scatter kernels superposed on the incident fluence. Since no experimental measurement method is available to directly confirm the separate subcomponents of photon scatter, a Monte Carlo simulation tool was developed to separately score them. This tool was used as the ‘gold standard’ for the development and validation of the TH method. The TH-predicted total patient-scattered photon fluence entering the EPID, as well its energy spectra, are compared with full Monte Carlo simulation (EGSnrc) for validation. A variety of phantoms are tested, including simple slab and anthropomorphic CT, as well as monoenergetic and polyenergetic beams with different field sizes. For these tests, the proposed TH method was demonstrated to be in good agreement with full Monte Carlo simulation, generally within 1%. Parameters of the TH method were optimized to maintain an accuracy of <2% while improving execution speed. The optimized TH method takes as little as ~70 seconds to execute on a single (non-parallel) CPU, while full MC simulations took over 30 hours. It is concluded that this patient-generated scattered photon fluence prediction algorithm is relatively fast and accurate and is suitable for implementation into clinical in vivo dosimetry approaches.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy (Ph.D.)
Discipline thesis:degree_discipline
Physics and Astronomy
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Guo, Kaiming
Advisor dc:contributor.supervisor
  • McCurdy, Boyd (Physics and Astronomy)
Committee members dc:contributor.committeemember
  • Elbakri, Idris (Physics and Astronomy)
  • VanUytven, Eric (Physics and Astronomy)
  • Lin, Francis (Physics and Astronomy)
  • Wang, Yang (Computer Science)
  • Warkentin, Brad (Department of Oncology, University of Alberta)

Subjects

dc:subject × 4

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1993/35125

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Guo, Kaiming. Developing a tri-hybrid algorithm to predict patient x-ray scatter into planar imaging detectors for therapeutic photon beams. Doctor of Philosophy (Ph.D.) thesis, 2020. https://hdl.handle.net/1993/35125