Back to search

University of Manitoba

Improving apparent inertia, damping, stability, and fault recovery performance in AC power networks with virtual synchronous machines

Abstract

dc:description.abstract

Traditional VSC control is of the “Grid Following Type” (GFL), where the turn-on pulses to the converter switches are determined based on fast synchronization with the external grid voltage phasor. GFL VSC has difficulty operating in very weak ac networks. In contrast, GFM-controlled VSC maintains an internal voltage phasor and has the potential to maintain system stability under such challenging network conditions. One important aspect of VSM type control of a VSC is that it imparts artificial inertia and damping behaviour to the VSC, which can have a significant impact on the VSMs ability to survive frequency events triggered by transient mismatch between generation and loads. This research investigates the disturbance ride through, stability and inertia support of using Virtual Synchronous machine (VSM) Grid-Forming (GFM) control on Voltage-Sourced Converters (VSC) High Voltage direct current (HVdc) transmission system. An adaptive fault ride-through control mode is proposed for VSM to improve its post-fault recovery transient and voltage phase angle jump ride-through performance. The EMT simulation shows the disturbance ride-through performance of VSM GFM with cascaded or switchable current control can be optimized by transiently changing the active power order and the damping coefficient in its power synchronization loop. Linearized models of the VSM with inertia and damping parameters are developed and validated using detailed EMT simulation for system small-signal stability analysis and controller parameter design under different system strengths. A current limiting feature is a necessity in any VSC due to the limited overcurrent ratings of the VSC’s power electronic switches. However, eigenvalue analysis reveals that the VSM can experience instability when connected to strong ac networks with the inclusion of the in-line cascaded current limiting. However, with proper controller tuning, a single suitable gain parameter set can nevertheless be found to allow stable operation under both weak and strong system strength. An important contribution of this research is the development of a novel method for online estimation of system inertia in inverter-based resources (IBRs). A small voltage or current probing signal that is different from the system frequency can be injected into a network to estimate the inertia from the GFM VSCs and synchronous machines. Since the injected signal is very small, the inertia of the GFM IBR can be conveniently measured during the steady-state operation without triggering other transient frequency support control. This can greatly improve the inertia measurement accuracy compared with the more conventional ROCOF observation method.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy (Ph.D.)
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lin, Ting
Advisor dc:contributor.supervisor
  • Gole, Aniruddha
Committee members dc:contributor.committeemember
  • Annakkage, Udaya (Electrical and Computer Engineering)
  • Fernando, Ioni (Electrical and Computer Engineering)
  • Sood, Vijay (Ontario Tech University)

Subjects

dc:subject × 6

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/37736

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Lin, Ting. Improving apparent inertia, damping, stability, and fault recovery performance in AC power networks with virtual synchronous machines. Doctor of Philosophy (Ph.D.) thesis, 2023. http://hdl.handle.net/1993/37736