Abstract
dc:description.abstractReinforcing steel bars are essential for connecting hollow-core slabs (HCS) to supporting structures, ensuring structural integrity and resistance to lateral in-plane loads. In Canada, 10M reinforcing bars are widely used to anchor HCS to supports. However, North American design provisions lack detailed guidelines for predicting the capacity and modes of failure of these connections, prompting further study to improve their reliability. This research evaluates the performance of reinforcing bar connections between HCS and masonry walls, focusing on common detailing practices in Western Canada. Twelve full-scale specimens were tested under in-plane tensile and shear forces, assessing variables including connection type (end-bearing or side-connection), load direction relative to the masonry wall, bar shape (L-shaped or U-shaped), and slab location in a ten-story building. Experimental results confirmed that all connections exceeded the code-prescribed tensile resistance for multi-storey buildings. Peak tensile resistance was primarily governed by friction and bond at the grout–HCS/masonry interface, with a notable contribution from the vertical wall reinforcement. Strain measurements and crack patterns demonstrated that the integrity ties remained inactive until cracking at the interface occurred. Once cracking initiated, the ties contributed to post-peak strength of the connection by restricting the HCS from sudden large displacements and loss of support, thereby enhancing structural integrity. The results further showed that L-shaped bars in end-bearing connections exhibited greater strain after peak load, while U-shaped bars facilitated more uniform load distribution, reducing strain localization. Additionally, specimens located at intermediate floors exhibited enhanced load-carrying capacity, with the fifth-floor specimens demonstrating a 248% increase in capacity compared to roof-level specimens without parapets. Shear tests of side-connections with hooked embedment length performed better than those anchored with adhesive, highlighting the significance of reinforcement continuity. End-bearing connections also demonstrated that bond and friction at grout-masonry interface along with vertical wall reinforcement were vital for resisting shear and maintaining connection ductility. The shear test results were consistent with the shear-friction model in Canadian standards, confirming its applicability for predicting HCS-to-masonry wall shear capacity. These findings enhance the understanding of connection behaviour and inform design practices for improved structural resilience
Degree
thesis:*- Level thesis:degree_level
- Master of Science (M.Sc.)
- Discipline thesis:degree_discipline
- Civil Engineering
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Alhatamleh, Yazan
- Advisor dc:contributor.supervisor
-
- El-Salakawy, Ehab
- Committee members dc:contributor.committeemember
-
- Fiorillo, Graziano (Civil Engineering)
- El-Gendy, Mohammed (Civil Engineering)
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1993/39060