Back to search

University of Manitoba

Accuracy of Bolton anterior and overall ratios on ClinCheck® Software in the crowded dentition

Abstract

dc:description.abstract

Introduction: The purpose of this study is to investigate the reliability of ClinCheck® Software on predicted mesiodistal tooth widths, assess the accuracy of Bolton ratios at 2 time points and whether crowding has any influence on Bolton ratios. Methods: Overall and anterior Bolton ratios were calculated for 29 patients with 5 to 8mm of crowding and undergone Invisalign treatment at a private orthodontic clinic in Canada. To evaluate the Bolton ratios, the mesiodistal widths were manually measured using an electronic caliper on 3D printed casts pre-treatment (T1) and at the last refinement scan (T2) as well as via ClinCheck® Software. Results: There are statistically significant differences in Bolton ratios between manual measurements and ClinCheck® Software for T1 overall ratio(p<.001), T2 anterior ratio (p<.001) and T2 overall ratio (p=.016, 1% of difference). Manual measurements indicate that crowding does not affect Bolton anterior (p=.172) and overall ratios (p=.938), however ClinCheck® measurements indicate that there are statistically significant differences in the anterior (p=.05) and overall (p<.001) Bolton ratios when crowding is involved (±1%). Tooth width measurements assessed by ClinCheck® Software tends to provide larger tooth widths compared with manual measurements. Although the overall reliability of tooth width measurements delivered by the ClinCheck® Software was excellent (ICC 0.994) the reliability of the Bolton ratios is uncertain with wide confidence intervals (0.267 – 0.949). Conclusions: Tooth width measurements assessed by the ClinCheck® Software are accurate and clinically acceptable when measuring individual teeth, except for first molars in both arches. ClinCheck® Software shows questionable reliability when Bolton ratios are estimated. Crowding does not influence Bolton ratios when calipers are used whereas ClinCheck® indicates there are statistically significant but in all probability not clinically relevant differences in ratios when crowding is present.

Degree

thesis:*
Level thesis:degree_level
Master of Dentistry (M.Dent.)
Discipline thesis:degree_discipline
Preventive Dental Science (Orthodontics)
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lee, Anita
Advisor dc:contributor.supervisor
  • Wiltshire, William
Committee members dc:contributor.committeemember
  • Lekic, Milos (Preventive Dental Science)
  • Todescan, Sylvia (Dental Diagnostics and Surgical Sciences)

Subjects

dc:subject × 2

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/39205

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Lee, Anita. Accuracy of Bolton anterior and overall ratios on ClinCheck® Software in the crowded dentition. Master of Dentistry (M.Dent.) thesis, 2025. http://hdl.handle.net/1993/39205