University of Manitoba
Behaviour of circular concrete slender columns reinforced with GFRP bars and spirals in single and double curvature
Abstract
dc:description.abstractRecent advancements in the concrete industry and the development of high-strength materials have enabled the design and construction of increasingly slender reinforced concrete (RC) columns. However, when traditional steel is used as internal reinforcement, these slender members remain highly susceptible to corrosion, particularly in aggressive environmental conditions. To address this challenge, fiber-reinforced polymer (FRP) reinforcement has gained significant attention as a durable, noncorrosive alternative to steel. Among the available FRP types, glass FRP (GFRP) bars are especially advantageous due to their large strain capacity, high tensile strength, and cost-effectiveness. These properties have promoted their use in structural applications where long-term durability is a primary concern. A total of eleven GFRP-RC columns were fabricated and tested under three different end moment ratios: 1.0, 0.5, and -0.5. The applied eccentricities included 0 mm (concentric), 60 mm (moderate), and 120 mm (large). Seven specimens were constructed with normal-strength concrete (NSC) having an average compressive strength of 41 MPa, while the remaining four were cast with high-strength concrete (HSC), averaging 74 MPa. The study investigated the effects of concrete compressive strength, end-moment ratio, and eccentricity on the axial capacity, stiffness, failure mechanisms, and second-order behaviour of slender GFRP-RC columns. Results demonstrated that HSC columns exhibited greater axial strength and enhanced post-peak performance but were prone to more brittle modes of failure. Two distinct failure types were identified: material failure, governed by concrete crushing, and instability failure, characterized by excessive lateral displacements. Columns subjected to unequal end moments, resulting in a non-uniform bending moment distribution along their length, exhibited enhanced stability and more controlled load responses. This was particularly evident in cases with double curvature, where improved performance was observed. In contrast, columns with equal end moments (moment ratio = 1.0), resulting in single curvature, demonstrated amplified second-order effects and increased vulnerability to instability-induced failure. Comparison between experimental results and available North American codes and standards for FRP-RC structures demonstrated that the predictions of axial capacity and flexural stiffness are overly conservative by current design provisions, primarily due to neglecting the compressive contribution of GFRP bars or considering it at limited strains.
Degree
thesis:*- Level thesis:degree_level
- Master of Science (M.Sc.)
- Discipline thesis:degree_discipline
- Civil Engineering
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Khamis, Ahmed
- Advisor dc:contributor.supervisor
-
- El-Salakawy, Ehab
- Committee members dc:contributor.committeemember
-
- Fiorillo, Graziano (Civil)
- El-Gendy, Mohammed (Civil Engineering)
Subjects
dc:subject × 8Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1993/39285